WilTec 50976 Operation Manual Download Page 7

remains waterproof also by high pressure 

water delivery 3 m height (dependent on pump output which is connected)

easy installation and maintenance of the filter 

WilTec pond filter functions

The WilTec pond filter clarifies the water in 3 phases:
 

1. The first stage is 

mechanic. 

The visible particles of dirt are removed by means of a 3-layer fil-

ter foam, arranged from coarse to fine.

2. The second stage is 

biologic. 

With the help of the so-called bio-balls (depending on model)

the settling of bio-organisms is stimulated. These bio-organisms remove the organic compon-
ents from the pond water (depending on model).

3. The third stage comprises a  

UVC water treatment.  

The UV light destroys swimming algae

and germs. The result is healthy water.

 

Commissioning

The pressure filter should be placed at least at a 2-meter distance from the pond edge. The
water outlet back to pond should be placed max. 2 m over the filter cover (0,2 bar water pres-
sure!).

The pump must be started first. The UVC lamp must not be operated as long as no water
flows through it. Do not use the UVC lamp if the lamp or the connections show damage signs.
Do not use the UVC-filter if there are people inside the water.

The built-in UV filter temperature sensor stops the UVC lamp. After cooling down, it is auto -
matically re-started.

The WilTec filter is delivered with all the necessary filter mats. Carefully wash the filter mats
with pond water before using. The bio-balls (depending on model) are placed at the bottom of
the filter, above put the grating with the protective tube for the UVC unit. Then put the filter
foam layers on it, arranged from fine to coarse. Put the cover lid on the housing and close the
filter with the supplied cramping bracket.

If properly installed, the filter is waterproof up to a 0,5 bar working pressure. The power supply
has to be equipped with an earth leakage circuit breaker that does not exceed 30 mA.

© by WilTec Wildanger Technik GmbH Item 50105, 50123, 50977–50980, 50121, 51042–51044

Page 7 

http://www.WilTec.de
http://www.aoyue.eu

 

04 2021

-1

http://www.teichtip.de

Summary of Contents for 50976

Page 1: ...d follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can...

Page 2: ...nd in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH K nigsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is...

Page 3: ...g environment If the cable or the plug is damaged due to external influences the cable must not be repaired It has to be replaced with a new one This work can be carried out only by an electrician The...

Page 4: ...before the water circulation has been carried out Please position the UVC filter on a safe and stable place because the pond filter light tube the tube that conveys the light is made of quartz glass t...

Page 5: ...k if all connections are well sealed By plugging in the power cable the device is put into operation Technical data Model Item number Power W Ten sion fre quency Suitable for up to Recom mended max fl...

Page 6: ...wer bed Function position Filter Function position Clean CPF 2500 CPF 5000 CPF 10000 CPF 15000 CPF 20000 CPF 30000 Water inlet from the pump into the filter Water flow from the filter into the pond Cl...

Page 7: ...ter pres sure The pump must be started first The UVC lamp must not be operated as long as no water flows through it Do not use the UVC lamp if the lamp or the connections show damage signs Do not use...

Page 8: ...large diameter step of the hose tail and saw off the other hose steps Use hose clamps to prevent the loosening of the hoses Connection to the cleaning outlet To install a permanent drain hose to the...

Page 9: ...p is a sealed filter system for biological and mechanical cleaning of pond water CPF 180 CPF 250 CPF 2500 5000 10000 15000 20000 30000 by WilTec Wildanger Technik GmbH Item 50105 50123 50977 50980 501...

Page 10: ...ms accumulate that reduce the nitrate to nitrogen E Pre cleaning of the pond water When the water flows out it is shortly exposed to the UV radiation emitted by the UV lamp As a result germs bacteria...

Page 11: ...positioned on a clean place If the outflow is blocked a higher pressure may result Higher pressure can lead to leaking spots in the filter and therefore to a complete emptying of the pump When the fi...

Page 12: ...ies CPF 2500 5000 10000 15000 20000 30000 have a fast cleaning function that can be activated with the aid of the crank Instead of the setting switch press button described above turn the crank handle...

Page 13: ...ost free place After work that requires the removal of the lid please make sure when attaching the cover lid that the sealing rings are fitted correctly Fit the clamp ring around the lid press on the...

Page 14: ...acid After this rinse the quartz glass from residues remaining from the cleaning agents After rinsing all parts are reassembled in reverse order The pump and the device are connec ted again to the po...

Page 15: ...article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correct disposal of t...

Reviews: