background image

8. Repeatedly open and close the water tap, to expel any remaining air from the piping system.
9. Open the tap, to release the water from the tank. If there are any pauses in between letting the

air out and starting the pump, the start-up pressure of the pressure switch needs to be in-
creased a bit or the pre-charge of the vessel needs to be decreased. Repeat these steps until
the pumps starts without any interruptions.

10. Check the connection on its tightness.
11. If everything has been correctly installed, the system is ready for use.
12. Check the pressure regularly during operation.

© by WilTec Wildanger Technik GmbH Item 50600, 50602, 50640–50643, 50645–50648

Page 5 

http://www.WilTec.de
http://www.aoyue.eu

 

01 2021

-1

http://www.teichtip.de

Summary of Contents for 50600

Page 1: ...w the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignific antly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ... found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany To shorten the waiting time and allow for a rapid on site transaction we ask you to call us previously or placing your order...

Page 3: ...tallation needs to be according to regional and national regulations Protect the vessel piping and any further components from cold temperatures and frost Product Information Expansion vessel The expansion vessel is designed for a maximal pressure of 5 4 bar and thus is tested for its tightness by the manufacturer with up to 5 4 bar water pressure The expansion vessel has a 32 89 33 25 mm connecti...

Page 4: ...water piping and the pressure switch converter or flow sensor is reduced Installation 1 Remove the protective cap and check the pre charge pressure 2 Check whether the pre charge pressure matches the one stated on the type label The max imal difference is 20 of the pressure indicated 3 With a lower pre charge the pressure needs to be adjusted according to the type plate After wards place the prote...

Page 5: ... needs to be in creased a bit or the pre charge of the vessel needs to be decreased Repeat these steps until the pumps starts without any interruptions 10 Check the connection on its tightness 11 If everything has been correctly installed the system is ready for use 12 Check the pressure regularly during operation by WilTec Wildanger Technik GmbH Item 50600 50602 50640 50643 50645 50648 Page 5 htt...

Page 6: ...rom the electricity and let it cool down Ensure that the pre charge pressure matches the one stated on the type label The max toler ance of the pressure is 20 The pre charge pressure should be lower than the start up pressure of the pressure switch and 0 1 0 2 bar below the start up pressure of the pump Never demount the vessel if it is not entirely empty and without pressure Check the pre charge ...

Page 7: ... by WilTec Wildanger Technik GmbH Item 50600 50602 50640 50643 50645 50648 Page 7 http www WilTec de http www aoyue eu 01 2021 1 http www teichtip de ...

Page 8: ...pliance is in conformity with the following European directives Cet appareil est conforme aux directives européennes 2014 68 EU Es ist nach folgenden harmonisierten Normen geprüft worden It has been tested with the following harmonised standards Il a été testé à partir des normes harmonisées suivantes EN 13445 1 2014 A1 2014 Bevollmächtigter für die Zusammenstellung der technischen Unterlagen Bern...

Reviews: