Fuel Oil Pump and Diesel Pump 

 ARTICLE 50591 und 50748 

 

 
 

 

 

               

 

   

TP04022                                                    TP04021 

 

Read and follow the operating instructions and safety information before using for the first time.  
 

Technical changes reserved! 

Due  to  further  developments,  illustrations,  functioning  steps  and  technical  data  can  differ 
insignificantly. 
 

Updating the documentation 

If you have suggestions for improvement or have found any irregularities please contact us. 
 
 

 

Summary of Contents for 50591

Page 1: ...structions and safety information before using for the first time Avant la mise en service lisez le mode d emploi et les consignes de s curit et respectez les Technische nderungen vorbehalten Durch st...

Page 2: ...olgenden Fehler melden Kundenbetreuung Wiltec Wildanger Technik GmbH e mail service wiltec info Tel 49 2403 55592 0 Einleitung Vielen Dank dass Sie sich zum Kauf dieses Qualit tsproduktes entschieden...

Page 3: ...Sie sicher dass die elektrischen Steckverbindungen im berflutungssicheren Bereich liegen bzw vor Feuchtigkeit gesch tzt sind Vor jeder Arbeit am Ger t Netzstecker ziehen Vermeiden Sie dass das Ger t...

Page 4: ...d nach dem Abk hlen schaltet sich die Pumpe wieder selbstst ndig ein Saugleitung Einen Saugschlauch Kunststoffschlauch mind 3 4 mit Spiralversteifung direkt oder mit einem Gewindenippel an den Saugans...

Page 5: ...hen kann Je nach Saugh he und Luftmenge in der Saugleitung kann der erste Ansaugvorgang ca 0 5 min 5 min betragen Bei l ngeren Ansaugzeiten sollte erneut F rdermedium aufgef llt werden Wird die Pumpe...

Page 6: ...Luft in der Saugleitung Dichte der Saugleitung berpr fen Saugventil undicht Saugventil reinigen Saugkorb Saugventil verstopft Saugkorb reinigen max Saugh he berschritten Saugh he berpr fen F rdermenge...

Page 7: ...f r diese Ger te Das Symbol auf dem Produkt oder seiner Verpackung weist darauf hin dass dieses Produkt nicht als normaler Haushaltsabfall zu behandeln ist sondern an einer Annahmestelle f r das Recyc...

Page 8: ...ntsprechenden Vorgaben gem den Richtlinien 2004 108 EC aufgrund seiner Konzipierung und Bauart sowie der von uns in Verkehr gebrachten Ausf hrung entspricht Bei der Bewertung des Produkts hinsichtlich...

Page 9: ...Read and follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical...

Page 10: ...lity product To minimize the risk of injury by means of fire or electric shock we urge that our clients take some basic safety precautions when using this device Please read the operation instructions...

Page 11: ...the device by using the power cable Make sure that the electrical plug connection is placed in a flood proof area and is protected from moisture Disconnect the mains plug before the maintenance work...

Page 12: ...n of the pump 1 Inside thread of the pump The suction hose that is used should have a suction valve In case the suction valve cannot be used a check valve should be installed in the suction line Posit...

Page 13: ...takes place Malfunctions of the pump Engine does not run Cause Corrections of malfunctions No supply power voltage Check voltage Pump impeller is blocked thermo controller is deactivated Dismantle the...

Page 14: ...parate collection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal household waste but must be disposed to a recycling...

Page 15: ...nformation before using for the first time Avant la mise en service lisez le mode d emploi et les consignes de s curit et respectez les Sous r serves de modifications techniques A cause d un d veloppe...

Page 16: ...de minimiser le risque de blessure par lectrocution ou par le feu nous vous prions de prendre toujours quelques mesures de s curit de base quand vous vous servez de l appareil Nous vous prions de lir...

Page 17: ...cords lectriques ne soient pas plac s dans un endroit sujet des inondations donc de ce qu ils soient prot g s de l humidit D branchez l appareil avant tout travail d entretien Evitez que l appareil so...

Page 18: ...taller la conduite au dessus de la hauteur de la pompe des bulles d air pourraient alors retarder ou emp cher l aspiration dans la conduite La conduite d aspiration et de pression sont installer de fa...

Page 19: ...ction thermique a fait arr ter la pompe D monter la pompe et la nettoyer Moteur ne marche pas Veuillez demander un lectricien d sign Pompe n aspire pas Causes Comment y rem dier Soupape d aspiration n...

Page 20: ...Le symbole inscrit sur le produit ou sur son emballage signale que le produit ne doit pas tre jet avec les ordures m nag res mais doit tre emmen dans un endroit responsable du recyclage d appareils le...