WilTec 50036 User Manual Download Page 2

  

© by WilTec Wildanger Technik GmbH  

 

Seite 2  

http://www.wiltec.info  

 
The  information  contained  in  this document  is  subject  to  change  without prior  notice.  No  part  of  this 
document can be copied or duplicated in another form without

 

the prior written consent of Wiltec Wil-

danger Technik GmbH. The Wiltec Wildanger Technik GmbH assumes no liability for any errors in this 
user manual or the connection diagram. 
Although Wiltec Wildanger Technik GmbH has made every effort to make sure that this user manual is 
complete, accurate and updated, errors cannot always be avoided. In the event of problems with this 
user manual please complete and send this form back to us. 
 

 

FAX-notification (++

+49 2403 55592-15

), 

 

 

 

from: ________________________________________

 

 

 

Name: 

________________ 

  

Firm:

_____________________ 

  

Tel/Fax:

__________________ 

  

I would like to report the following mistakes: 

 

 

 

 

 

 

 

  
 
 
 
 
 
 
 

 
___________________________________________________________________ 
  

Customer Service Wiltec Wildanger Technik GmbH  
e-mail: 

[email protected]

 

Tel:++ +49 2403 55592-0 

Introduction 

 
Thank  you  for  purchasing  this  quality  product.

 To minimize  the  risk  of  injury  by  means  of  fire  or 

electric  shock  we  urge  that  our  clients  take  some  basic  safety  precautions  when  using  this 
device. Please read the operation instructions carefully and make sure you have understood its 
content.

 

Always use a grounded power connection with the appropriate mains voltage. You can find the corre-
sponding  mains  voltage  on  the  type  plate.  If  you  have  any  doubts  about  the  connection  being 
grounded, have it checked by a qualified professional. Never use a faulty electric cable. 
Do not inspect the electrical part of the pressure pond filter in a wet or damp environment or when you 
are wet yourself and protect it from direct sunlight. Install this device in a safe location so that nobody 
can  step  on  the  cable,  fall  over  or  damage  it.  Disconnect  the power  plug  before  cleaning  it  and use 
only  a damp  cloth for cleaning. Avoid using cleaning  agents and make sure that no liquid enters the 
electrical part of the pump. 
The electric part of the device contains no parts that can be inspected or serviced by the user. Leave 
the maintenance, adjustment and repair to qualified technical personnel. In case of unauthorised inter-
vention the 2-year warranty is no longer valid! Keep these operation instructions safe. 
 

 

Summary of Contents for 50036

Page 1: ...ty information before using for the first time Avant la mise en service lisez le mode d emploi et les consignes de sécurité et respectez les Technische Änderungen vorbehalten Durch stetige Weiterentwicklungen können Abbildungen Funktionsschritte und technische Daten ge ringfügig abweichen Aktualisierung der Dokumentation Haben Sie Vorschläge zur Verbesserung oder haben Sie Unregelmäßigkeiten festg...

Page 2: ...s quality product To minimize the risk of injury by means of fire or electric shock we urge that our clients take some basic safety precautions when using this device Please read the operation instructions carefully and make sure you have understood its content Always use a grounded power connection with the appropriate mains voltage You can find the corre sponding mains voltage on the type plate ...

Page 3: ...tated in the instructions for use You are responsible for the safety of the working environment If the cable or the plug is damaged due to external influences the cable must not be repaired It has to be replaced with a new one This work can be carried out only by an electrician The voltage indicated on the type plate of the device of 230 Volt alternating voltage has to cor respond to the existent ...

Page 4: ...Switch on your power source 1 4 Switch your unit on 1 5 You will hear an alarm sounding due to low temperature humidity 1 6 Press any of the green buttons to cancel the alarm 1 7 By opening the incubator and filling the water channels you will notice the humidity reading increase 1 8 Let the unit run for 2 hours to note the egg turner turning 2 Setting the temperature 2 1 Push SET once 2 2 Push or...

Page 5: ...ater channels every 4 to 5 days and at day 18 when I remove the egg trays I over fill them to increase the humidity to about 65 5 Calibrating temperature sensor reading CA The thermometer correct reading is set at 0o C The reading given by the thermometer can be adjusted if you find that the temperature reading is incorrect using a calibrated thermome ter 5 1 Calibrating the temperature sensor mea...

Page 6: ...3 1 above AL Low temperature alarm parameter setting 1o C 3 2 above AH Higher temperature alarm parameter set ting 1o C 4 1 above AS Low humidity alarm parameter setting 45 5 1 above CA Calibrating the temperature sensor reading 0o C 6 above HS Temperature higher limit set 39 5o C 6 above LS Temperature lower limit set 30o C 7 above HU Heating starts 18 7 above HD Heating stops 11 9 Using your Inc...

Page 7: ... the floor of the incubator Place the Condy s crystals into the dish first and then pour the formalin over it Shut the incubator door quickly and vacate the room For proper fumigation run the machine normally with the correct temperature and humidity After 20 minutes open the vents or the door and air the machine for a few minutes Again vacate the room Healthy stock It is important that eggs from ...

Page 8: ...reditary so continual use of badly shaped eggs perpetuates and increases this fault Only eggs with good shell texture should be used for hatching Shell texture is not heritable however weak shelled eggs may crack enabling bacteria to enter or excessive moisture to be removed from the egg Porous shelled eggs increase the rate of moisture loss during storage and incubation Hair cracks that are too s...

Page 9: ...ng compartment or prolonged delays during transfer resulting in chilling may cause embryo deaths Excessive inbreeding of poultry may result in lethal or semi lethal genes which also cause mortality during incubation Consistent temperature A hen s normal body temperature varies between 40 5 and 41 7o C depending on the bird and her degree of activity at the time The optimum temperature at the centr...

Page 10: ...ings which indi cate very early embry onic death a Incubator temperature too high or low a Check thermometers thermostats and electricity supply follow manu facturer s instructions b Incorrect fumigation procedure b Use the correct amount of fumi gant Do not fumigate between 24 and 96 hours after setting c As in 1 g c As in 1 g 3 Many dead in shell a As in 2 a a As in 2 a b Eggs not properly turne...

Page 11: ...n incubator c As in 4 d Too much fumigant left in hatcher d As in 2 b Heavy breathing chicks e Too much moisture in hatcher e As in 4 f Possibly infectious disease f Send chicks to a veterinary labor atory for diagnosis g Low average temperature during period of incubation g As in 2 a Mushy chicks h Incubator has poor ventilation i Omphalitis navel infection h As in 3 d i Carefully clean out and f...

Page 12: ...ion period As you learn you ll have these notes to look back on They will be the most valuable tool that you can have It won t be long until you can say I know what happened all I need to do is change this one little thing Soon you will be able to make adjustments by knowing what to do instead of guessing 5 How do I check humidity Humidity is checked by way of a hygrometer wet bulb thermometer in ...

Page 13: ...k time to orient itself inside the egg before piping After day 18 KEEP THE INCUBATOR CLOSED except to add water This will help bring the humidity up to help the chicks hatch I know it will kill you not to open the incubator 1000 times when it s this close to hatch time but it s not good for the chicks If you haven t bought an incubator yet invest the extra couple bucks in the picture window model ...

Page 14: ...have been penetrated the egg is likely to have become contaminated with pathogens and the yolk embryo or blood vessels may have been physically damaged Hatchability is greatly reduced A piped egg which is being parent or broody incubated and becomes damaged should be moved to a hatching incubator Records Accurate and detailed records are very important in incubation All eggs should be individually...

Page 15: ...em für diese Geräte Das Symbol auf dem Produkt oder seiner Verpackung weist darauf hin dass dieses Produkt nicht als norma ler Haushaltsabfall zu behandeln ist sondern an einer Annahmestelle für das Recycling von elektrischen und elektronischen Geräten abgegeben werden muss Durch Ihren Beitrag zum korrekten Entsorgen dieses Produkts schützen Sie die Umwelt und die Gesundheit Ihrer Mitmenschen Umwe...

Page 16: ... bestimmungsgemäßer Verwendung den grundlegenden Anforderungen und den weiteren entsprechenden Vorgaben gemäß den Richtlinien 2006 95 EG und 2006 42 EG aufgrund seiner Konzipierung und Bauart sowie der von uns in Verkehr gebrachten Ausführung ent spricht Bei der Bewertung des Produkts hinsichtlich der Anforderung der Richtlinien kamen die folgenden Standards zur Anwendung EN 60335 1 2012 EN 60335 ...

Reviews: