Operating Booster 430

First of all choose the right battery voltage (12 V or 24 V), then connect the battery clamps
with the battery poles.

Switch the rocker switch  

4

  to “CB,”  switch  

2

  to  MIN or MAX,  then switch  

3

  to  “1”  (normal

charge) or “2” (boosted charge).

Then turn the charger on by switching the main switch 

5

 to “on” (“I”); the charging process will

start.

If you wish to start a car engine, push switch 

4

 to “START,” then switch 

5

 to “on” (“I”), charge

the battery for 2 min. 

Then disconnect the charger from the battery

 and try starting the car

engine for max. 4–5 s. If the engine does not start after 3–4 tries, wait 10 more minutes before
trying to boost charge the car battery again.

Control panel elements and their functions

№ Name/function

1

Amperemeter, measures the amperage

2

Operating switch 2: Min/Max

When choosing “START”, switch to “Max.”

When choosing “CB” (“charge battery”), it means: “MIN” will charge in boost phase
(when large capacity batteries are deeply discharged and turned onto the more power-
ful charging options, 2 or MAX, overload protection may be activated); in this case
charge the battery for a short period on “MIN” option. If the battery charges without any
disruptions, it can be switched to “MAX.”

3

Operating switch 3: level 1/2 (I/II)
“1” = normal charging, “2” = fast charging
(This switch is only used for charging purposes; when starting, this switch has no function.)

4

Operating switch 4:
“CB” = charge battery; “Start”

5

Main switch

© by WilTec Wildanger Technik GmbH 

Item 30560, 30562 

Page 5

http://www.WilTec.de
http://www.aoyue.eu

 

03 2021

-1

http://www.teichtip.de

Summary of Contents for 430

Page 1: ...ollow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignific antly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...uages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany To shorten the waiting time and allow for a rapid on site transaction we ask you to call us previously or placin...

Page 3: ... down and to have enough airflow Never cover the airing holes The charger device is only allowed to be used indoors The device needs to be kept away from moisture and humidity If the device should get wet there is a danger of being electro cuted When the battery is charged small amounts of gas are released from the battery acid which is normal The gas leak is noticeable through the formation of bu...

Page 4: ...with the booster please note 1 If the engine is bigger it is better to boost charge it for 15 min prior to trying to restart it 2 In case you wish to start a diesel engine let the glow plugs preheat before trying to start the engine For charging connect the red battery clamp with the positive terminal and the black clamp with the negative terminal never swap them Connect the connection cables of t...

Page 5: ... Control panel elements and their functions Name function 1 Amperemeter measures the amperage 2 Operating switch 2 Min Max When choosing START switch to Max When choosing CB charge battery it means MIN will charge in boost phase when large capacity batteries are deeply discharged and turned onto the more power ful charging options 2 or MAX overload protection may be activated in this case charge t...

Page 6: ...n operating switch 1 to START charge the battery for 2 min Then disconnect the charger from the battery and try starting the car engine for max 4 5 s If the engine does not start after 3 4 tries wait 10 more minutes before trying to boost charge the car battery again Control panel elements Name Name 1 Operating switch 6 DC 12 V output 2 Amperemeter measures the amperage 7 AC 230 V input 3 Fuse 8 T...

Page 7: ...Circuit diagram by WilTec Wildanger Technik GmbH Item 30560 30562 Page 7 http www WilTec de http www aoyue eu 03 2021 1 http www teichtip de ...

Page 8: ...s out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correct disposal of this art icle you protect the environment and the health of your fellow men Environment and health are threatened by inappropriate disposal Material recycling helps reduce the consumpti...

Reviews: