WilTec 2800 Operation Manual Download Page 2

The information contained in this document is subject to change without prior notice. No part of this
document  can be copied or duplicated in another  form withoutthe  prior written consent of  WilTec
Wildanger Technik GmbH. The WilTec Wildanger Technik GmbH assumes no liability for any errors in
this user manual or the connection diagram.
Although WilTec Wildanger Technik GmbH has made every effort to make sure that this user manual
is complete, accurate and updated, errors cannot always be avoided.  In the event of problems with
this user manual please complete and send this form back to us.

FAX-notification (++

+49 2403 55592-15

), 

 
from: ________________________________________
 
Name: 

________________

 

Firm:

_____________________

 

Tel/Fax:

__________________

 

I would like to report the following mistakes: 

 
 
 
 

_______________________________

 

 ____________________________________

 

 

 

Customer Service WilTec Wildanger Technik GmbH 
e-mail: 

[email protected]

Tel:++ +49 2403 55592-0

Introduction

Thank you for purchasing this quality product.

 To minimize the risk of injury by means of fire or

electric shock we urge that our clients take some basic safety precautions when using this
device. Please read the operation instructions carefully and make sure you have understood its
content.

Always use a grounded power connection with the appropriate mains voltage. You can
find the corresponding mains voltage on the type plate. If you have any doubts about the

connection   being   grounded,   have   it   checked   by   a   qualified  professional.   Never   use  a
faulty electric cable.

Do   not   inspect   the   electrical   part   of   the   pressure   pond   filter   in   a   wet   or   damp
environment or when you are wet yourself and protect it from direct sunlight. Install this

device in a safe location so that nobody can step on the cable, fall over or damage it.
Disconnect the power plug before cleaning it and use only a damp cloth for cleaning.
Avoid using cleaning agents and 

make sure that no liquid enters the electrical part of the pump.

The electric part of the device contains no parts that can be inspected or serviced by the user. Leave
the   maintenance,   adjustment   and   repair   to   qualified   technical   personnel.   In   case   of   unauthorised
intervention the 2-year warranty is no longer valid! Keep these operation instructions safe.

© by WilTec Wildanger Technik GmbH 

Seite 14

http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de

Summary of Contents for 2800

Page 1: ...e Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us by WilTec Wildanger Technik GmbH Seite 13 http www WilTec de http www aoyue eu http www teichtip de ...

Page 2: ...ck we urge that our clients take some basic safety precautions when using this device Please read the operation instructions carefully and make sure you have understood its content Always use a grounded power connection with the appropriate mains voltage You can find the corresponding mains voltage on the type plate If you have any doubts about the connection being grounded have it checked by a qu...

Page 3: ...ntact the manufacturer to get missing labels in order to replace them PROJECTILE HAZARDS 1 Failure of the workpiece accessories or even of the inserted tool itself can generate high velocity projectiles 2 Always wear impact resistant eye protection during the operation of the power tool The grade of protection required should be assessed for each use 3 Ensure that the workpiece is securely fixed H...

Page 4: ...wing REPETITIVE MOTIONS HAZARDS 1 When using a power tool the operator can experience discomfort in the hands arms shoulders neck and other parts of the body due to constant vibrations 2 While using an assembly power tool the operator should adopt a comfortable posture while main taining secure footing and avoiding unnatural or off balanced postures The operator should change posture during extend...

Page 5: ...ion or suppression of airborne dust or fumes should be correctly used and maintained in accordance with the manufacturer s instruc tions 4 Use respiratory protection in accordance with employer s instructions and as required by occupa tional health and safety regulations NOISE HAZARDS 1 Exposure to high noise levels can cause permanent disabling hearing loss and other problems such as a tinnitus r...

Page 6: ...NAL SAFETY INSTRUCTIONS PNEUMATIC POWER TOOL 1 Air under pressure can cause severe injury 2 Always shut off air supply drain hose of air pressure and disconnect the tool from air supply when not in use before changing accessories or when making repairs 3 Never direct air at yourself or anyone else 4 Whipping hoses can cause severe injury Always check for damaged or loose hoses and fittings 5 Cold ...

Page 7: ... 25 4 1 2180 14 4200 41 8 12 108 119 11 760 19 mm 3 4 25 4 mm 1 1600 7 4600 33 6 10 98 109 6 2800 9 5 mm 3 8 12 7 mm 1 2 520 1 6 9000 13 6 8 96 107 4 3600 12 7 mm 1 2 850 3 7500 18 6 8 97 108 4 3900 12 7 mm 1 2 900 2 1 8000 18 6 8 94 105 4 Emission values A noise according to EN ISO 15744 See Technical Data table by WilTec Wildanger Technik GmbH Seite 19 http www WilTec de http www aoyue eu http w...

Page 8: ...IPTION This tool has a reversible spindle driving a hammer which periodically strikes an anvil which includes a drive adapter for the purpose of tightening or loosening nuts and bolts without producing any major torque reaction on the power tool OPERATION INSTRUCTIONS MAIN APPLICATIONS This product is the perfect assembly tool when working on cars heavy trucks boats construction ma chines steel be...

Page 9: ...larger compressor for each tool INSERTED TOOLS Only use sockets or adapters which are in good working condition The intended socket and adapter for this air tool is stated as square drive included in the technical data table SAFETY Wear proper eye protection ear muffs mouth muffle and gloves at all times when operating this tool to minimize risks of injury The working place must be well ventilated...

Page 10: ...the R in dicates reverse Forward is defined as clockwise direction seen from the operator s position MAINTENANCE LUBRICATION Before connecting the hose apply 4 to 5 drops of 10 spindle oil at the air inlet Use of thicker oil can lead to reduced performance or malfunction If thicker oil is used by accident wash it away immedi ately Also oiling is necessary after every 3 4 hours of operation STORAGE...