NOTICE! The specifications applicable to
swimming pools also apply to accessible
basins.
1.10
Removal
ƒ
Wear protective equipment!
ƒ
Product without plug:
Have the connection
cable disconnected from the mains by a quali-
fied electrician.
ƒ
Depending on the operating mode and dura-
tion, the housing parts become hotter than
40 °C (104 °F).
–
Only touch the product by the carrying
handle.
–
Allow product to cool down.
ƒ
Clean the device thoroughly.
ƒ
If there is a risk of germ formation, observe
the following points:
–
Ensure sufficient air exchange.
–
Wear a breathing protection mask e.g. 3M
Series 6000 with filter 6055 A2
–
Disinfect product.
1.11
Clean and disinfect
ƒ
Wear protective equipment!
The protective equipment prevents contact
with germs that are hazardous to health and
the disinfectant.
ƒ
If a disinfectant is used, follow the manufac-
turer's instructions!
–
Wear protective equipment according to the
manufacturer's instructions! If in doubt, ask
your specialist dealer.
–
Inform all persons about the disinfectant
and how to use it correctly!
1.12
Maintenance tasks
ƒ
Wear protective equipment!
ƒ
Carry out maintenance work in a clean, dry and
well-lit place.
ƒ
Only original parts of the manufacturer may be
used. The use of any non-original parts re-