en
Installation and electrical connection
16
WILO SE 02/2022
WARNING
Risk of fall!
The pump must be never carried by using motor hooks: these are only designed to
lift the motor alone.
7.3
Pipe connection
ƒ
Connect the pump to the pipes by using appropriate counterflanges, bolts, nuts
and gaskets.
CAUTION
Tightening of screws or bolts must not exceed.
Configuration PN16 / PN25
M10 – 20 N.m - M12 – 30 N.m
Configuration PN40
M12 – 50 N.m - M16 – 80 N.m
Use of impact wrench is prohibited.
ƒ
The circulation sense of the fluid is indicated on the identification label of the
pump.
ƒ
Pump must be installed in such a way that it is not stressed by the pipework. The
pipes must be attached so that the pump does not bear their weight.
ƒ
It is recommended that isolation valves be installed on the suction and discharge
side of the pump.
ƒ
Use of expansion joints may mitigate noise and vibration of the pump.
ƒ
As regards the nominal cross-section of the suction pipe, we recommend a cross-
section at least as large as that of the pump connection.
ƒ
A check valve could be placed on the discharge pipe in order to protect the pump
against hammer shock.
ƒ
For direct connection to a public drinking water system, the suction pipe must also
have a check valve and a guard valve.
ƒ
For indirect connection via a tank, the suction pipe must have a strainer to keep
any impurities out of the pump and a check valve.
7.4
Motor connection for bare-shaft
pump (without motor)
ƒ
Remove coupling guards.
NOTICE
Coupling guards can be removed without entirely unscrewing screws.
ƒ
Install the motor on the pump by using screws (FT lantern size – see product des-
ignation) or bolts, nuts and handling devices (FF lantern size – see product desig-
nation) provided with the pump : check motor power and dimension in Wilo cata-
logue.
NOTICE
Depending on fluid characteristics, motor power could be modified. Contact The
Wilo Customer Services if necessary.
ƒ
Close the coupling guards by screwing all screws provided with the pump.
Summary of Contents for Wilo-Helix V FIRST V 2.0-VE 10
Page 2: ......
Page 3: ...Fig 1 ...
Page 4: ...Fig 2 ...
Page 7: ...7 English 8 ...
Page 22: ......