Installation and operating instructions Wilo-Star-Z 15 TT

9

Engl

is

h

Installation

Symbols

The following symbols are displayed in the menu:

5 Installation

5.1 Mechanical installation

Installation site

Choose a weatherproof, frost-free, dust-free and well-venti-
lated room for the installation. Make sure that the installation site 
is easily accessible.

Menu clock

Set the current time

Menu timer function

Set the parameters.

- Set the 3 possible switch-on times.

- Set the 3 possible switch-off times.

- Timer function switched off.

- Timer function switched on.

Menu temperature control

Set the parameters.

- Switch thermal disinfection on/off.

Basic displa

y (exit menu)

The following are displayed alternately on 
the basic display:
- time and set temperature of the tempera-

ture control system.

- Thermal disinfection ON (does not appear 

if the thermal disinfection is switched off)

-

11:30

65 °C

Danger: 

Before starting work, make sure that the pump 

has been disconnected from the power supply.

Caution: 

Dirt can cause pump failure. Flush the pipe sys-

tem before installation.

Summary of Contents for Star-Z 15 TT

Page 1: ...amiento it Istruzioni di montaggio uso e manutenzione pt Manual de Instalação e funcionamento el Οδηγίες εγκατάστασης και λειτουργίας sv Monterings och skötselanvisning da Monterings og driftsvejledning hu Beépítési és üzemeltetési utasítás pl Instrukcja montażu i obsługi cs Návod k montáži a obsluze ru Инструкция по монтажу и эксплуатации lv Uzstādīšanas un ekspluatācijas instrukcija sl Navodila ...

Page 2: ...ge 10 Faults Page 14 The menu Page 8 Type key Page 6 To set the current time Page 11 Set the timer function Page 12 Setting continuous operation Page 13 Setting the temperature control system Page 12 Switch thermal disinfection on or off Page 13 The red button Page 8 Electrical connection Page 11 Safety Page 5 How it works Page 7 Installation Page 9 Basic display exit menu Page 9 Settings Page 11 ...

Page 3: ...s Qualification The pump must only be installed by qualified personnel The power may only be connected by qualified personnel Regulations The current version of the following regulations must be observed when installing the equipment Accident prevention regulations DVGW worksheet W551 in Germany VDE 0370 Part 1 Other local regulations e g IEC VDE etc Conversion spares The pump must not be technica...

Page 4: ...gainst water spray Do not immerse in water or other fluids 3 Technical data 3 1 Type key 3 2 Connections 3 3 Data See name plate or Wilo catalogue for further information Star Z Series Standard drinking water circulation pump glandless pump 15 Nominal width of the connecting pipe mm TT Timer thermostat Star Z 15 TT Screwed connection 20 R1 Star Z 15 TT Mains voltage 1 230 V 50 Hz Protection class ...

Page 5: ...witched on and off automatically This function ensures that from a set temperature of more than 55 C the danger of germs forming in the circulation system is reduced DVGW requirement lime deposits are reduced the power consumption is reduced Works setting temperature control system switched off Thermal disinfection The boiler heats up periodically to approximately 70 C for ther mal disinfection pu...

Page 6: ...mer function it switches on automatically for 10 seconds every 60 minutes This automatic function cannot be switched on or off 4 3 The menu The red button All menu settings are made using the red button Note Alearningphasestartsafter the thermal disinfection function is activated In this case the pump switches itself on for 10 minutes every 20 minutes If the temperature increases the time is store...

Page 7: ...the 3 possible switch on times Set the 3 possible switch off times Timer function switched off Timer function switched on Menu temperature control Set the parameters Switch thermal disinfection on off Basic display exit menu The following are displayed alternately on the basic display time and set temperature of the tempera ture control system Thermal disinfection ON does not appear if the thermal...

Page 8: ... of flow 7 Fit the thermal insulation shell Connect 8 Connect the pipework Note The stop valve and non return valve are already installed No other stop valves are necessary A B Caution Do not damage the housing and seal Replace damaged seal Caution If the cable screw connection is in the wrong position water can penetrate into the pump and destroy the motor or the electronics 1 Note To close the s...

Page 9: ... 5 mm 4 Secure the cores with the cable clips L phase N neutral conductor earth 5 Firmly tighten the cable connection 6 Close the terminal box 7 Set parameters Page 11 5 3 Filling and ventilation 1 Fill the system 2 The pumpvents automatically Thepumpwillnot be damaged if it runs dry briefly 6 Settings 6 1 To set the current time Danger Only a qualified electrician may work on the elec trical conn...

Page 10: ...ime 6 Set hours for the first switch off time 7 Set minutes for the first switch off time Warns against a non DVGW compliant setting and appears if the switch off time is more than 8 hours 8 Repeat steps 4 to 7 for switch on and switch off times 2 and 3 9 Select the basic display 5 sec 5 sec AA2 1 2 Select control system flashes 3 Set temperature Selection range 40 70 C Means that the temperature ...

Page 11: ...w 55 C 4 Switch thermal disinfection on or off 5 Select the basic display AA1 1 2 Select timer function flashes 3 Select flashes to switch off the timer function 4 Select control system flashes 5 Select to switch off the tempera ture control system 6 Select off flashes to switch off the thermal disinfection function 7 Select the basic display 5 sec 5 sec 5 sec On Caution Never clean the display wi...

Page 12: ...terrupted Restore power supply Additional dis play symbols are shown Frequency superimposed when operating in an industrial environ ment or near radio transmitters This fault does not affect the pump function Pump does not start Power supply interrupted short cir cuit or fuses defective Have the power supply checked by a qualified electrician Timer function has switched off automatically Check the...

Page 13: ...annungsrichtlinie 2006 95 EG _ Low voltage 2006 95 EC _ Basse tension 2006 95 CE _ Elektromagnetische Verträglichkeit Richtlinie 2004 108 EG _ Electromagnetic compatibility 2004 108 EC _ Compabilité électromagnétique 2004 108 CE EG KONFORMITÄTSERKLÄRUNG EC DECLARATION OF CONFORMITY DECLARATION DE CONFORMITE CE Als Hersteller erklären wir hiermit dass die Nassläufer Umwälzpumpen der Baureihe We the...

Page 14: ... 23 889500 India v v Pune 411019 T 91 20 27442100 Indonesia vh v Jakarta Timur 13950 T 62 21 7247676 Ireland WILO Ireland T 353 61 227566 Italy v w Milano T 39 25538351 Kazakhstan WILO Central Asia 050002 Almaty T 7 727 2785961 Korea v F w T 82 51 950 8000 Latvia w 1019 Riga T 371 6714 5229 Lebanon WILO LEBANON SARL z Lebanon T 961 1 888910 Lithuania X w 03202 Vilnius T 370 5 2136495 Morocco T 212...

Page 15: ...WILO SE Nortkirchenstraße 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com Pioneering for You ...

Reviews: