Installation and operating instructions • Wilo-Padus MINI3 • Ed.01/2022-06

9

S1
S3

OFF!

ON

386 mm

15 in

315 mm

12,5 in

75 mm

3 in

245 mm

9,5 in

min. 500x500 mm

min. 20x20 in

min. 500 mm

min. 20 in

Fig. 2: Padus MINI3-

M

: Installation dimensions and switching

points

ON

Switch-on level

OFF

Switch-off level

Fill level above: Continuous duty (operating mode im-
mersed)

Fill level below: Intermittent periodic duty (operating mode
non-immersed)

S1
S3

OFF!

ON

407 mm

16 in

335 mm

13 in

96 mm

4 in

245 mm

9,5 in

min. 500x500 mm

min. 20x20 in

min. 500 mm

min. 20 in

Fig. 3: Padus MINI3-

V

: Installation dimensions and switching points

ON

Switch-on level

OFF

Switch-off level

Fill level above: Continuous duty (operating mode im-
mersed)

Fill level below: Intermittent periodic duty (operating mode
non-immersed)

Site is prepared.

Pressure pipe properly installed.

1.

Screw the discharge pipe fully into the pump’s discharge con-
nection.

2.

Position the pump at the installation site.

CAUTION! Use a hard surface or underlay at the installation
site to prevent sinking on soft substrate.

3.

Connect the discharge pipe to the pressure pipe (e.g. using a
flexible hose section).

4.

Secure the connection cable to the pressure pipe and route it
to the socket/power supply.

Pump is installed.

5.2.2

Portable wet well installation

The pump can be installed at any location on the application site
when carrying out portable wet well installation. Observe and ad-
here to the following points:

Secure the pump against falling over and moving (creeping)
during use.

Secure the pressure hose to the hose connection.

Site is prepared

Pressure hose to be used: Min. inside diameter 1½"

Hose clip to be used: 40 − 60 mm inside diameter (1.6 − 2.4 in)

Hose connection to be used: G 1½" (with male thread)

1.

Attach the hose connection.
Twist the hose connection into the pressure port as far as it
will go.

2.

Slide the hose clip over the pressure hose.

3.

Slide the pressure hose onto the hose connection at the pres-
sure port.

4.

Secure the pressure hose to the hose connection using the
hose clip.

5.

Position the pump at the installation site.

CAUTION! Use a hard surface or underlay at the installation
site to prevent sinking on soft substrate.

6.

Lay the pressure hose and fasten it in the appropriate place
(e.g. drainage). 

CAUTION! If the pump is placed in a full

chamber, hold the pump at a slight angle when immersing.
This causes the air to escape from the pump!

7.

Route the connection cable to the socket/power supply.

Pump is installed.

5.3

Electrical connection

Mains connection with correctly installed protective earth con-
ductor.

Residual-current device (RCD) is installed with 30 mA.

Mains connection fuse protection: max. 16 A.

Voltage (U) and frequency (f) data on the rating plate corres-
pond to the data of the mains connection.

Do 

not

 connect the pump if:

The connection cable is damaged
Have the connection cable replaced by a qualified electrician or
the customer service.

A standalone inverter is in use
Stand-alone inverters are used in autonomous power supplies,
e.g. solar power supply, and can generate overvoltages. Over-
voltages can destroy the pump.

A multiple plug socket or power strip is in use

An energy-saving plug is in use
This reduces the energy supply to the pump and the pump may
heat up too much.

Operation on start-up controls
The pump is not suitable for operation on a frequency converter
or a soft start control.

Explosive atmospheres
Do not connect and operate the pump inside potentially ex-
plosive atmospheres!

5.3.1

Connection: Pump with plug

Provide for a socket (type E or type F) with earthing contact. To
connect the pump, insert the plug into the socket.

Summary of Contents for Padus MINI3 5M Series

Page 1: ...Pioneering for You Wilo Padus MINI3 3119684 Ed 01 2022 06 en Installation and operating instructions...

Page 2: ...Padus MINI3 https qr wilo com 930...

Page 3: ...a 7 2 3 Type key 7 2 4 Scope of delivery 7 2 5 Functions 7 3 Application use 7 3 1 Intended use 7 3 2 Improper use 8 4 Transport and storage 8 5 Installation and electrical connection 8 5 1 Installati...

Page 4: ...in grey Damage to property Safety instructions start with a signal word and are displayed without a symbol Signal words DANGER Failure to follow the instructions will result in serious injuries or dea...

Page 5: ...xchange Wear a breathing protection mask e g Half mask 3M series 6000 with filter 6055 A2 1 9 Electrical connection Do not connect products with a damaged connection cable Have the connection cable re...

Page 6: ...ation Padus MINI3 V Padus MINI3 M 1 2 3 3 4 5 5 6 6 Fig 1 Overview 1 Handle 2 Motor housing 3 Discharge connection 4 Pump housing 5 Float switch 6 Connection cable Padus MINI3 V P Drainage pump with v...

Page 7: ...ate Speed See rating plate Discharge connection G 1 IG Operating mode immersed S1 Operating mode non im mersed S3 20 2 Fluid temperature 3 40 C 37 104 F Fluid temperature short term for 3 min Max imme...

Page 8: ...ging for transport and storage Pack the pump when dry Wet or humid pumps may soften the packaging Storage conditions Maximum 15 60 C 5 140 F max humidity 90 non condensing Recommended 5 25 C 41 77 F r...

Page 9: ...be used G 1 with male thread 1 Attach the hose connection Twist the hose connection into the pressure port as far as it will go 2 Slide the hose clip over the pressure hose 3 Slide the pressure hose...

Page 10: ...n bn L phase Blue bl N neutral conductor Green yellow gn ye Earth protective earth con ductor Pump with three phase AC motor The pump is suitable for connection to a clockwise rotating field Check the...

Page 11: ...device thoroughly 7 1 Stationary wet well installation 1 Close the gate valve in the inlet and pressure pipe 2 Switch off pump Pump with a plug Pull the plug Pump firmly connected without plug Discon...

Page 12: ...ere dirt and encrustations remove the lower part of the pump housing and clean the pump interior Fig 5 Padus MINI3 V View from below 1 Place the pump on a firm surface in a horizontal position 2 Secur...

Page 13: ...r silted clogged Shut down the pump remove it and clean it 4 Float switch not operational The float switch must be able to move freely Pump starts up but does not supply fluid 1 Pressure pipe discharg...

Page 14: ...following points Hand over these products at designated certified collection points only Observe the locally applicable regulations Please consult your local municipality the nearest waste disposal s...

Page 15: ......

Page 16: ...Pioneering for You Local contact at www wilo com contact WILO SE Wilopark 1 44263 Dortmund Germany T 49 0 231 4102 0 T 49 0 231 4102 7363 wilo wilo com www wilo com...

Reviews: