background image

Pioneering for You

·

Wilo-Padus MINI3

3119684 • Ed.01/2022-06

en

Installation and operating instructions

Summary of Contents for Padus MINI3 5M Series

Page 1: ...Pioneering for You Wilo Padus MINI3 3119684 Ed 01 2022 06 en Installation and operating instructions...

Page 2: ...Padus MINI3 https qr wilo com 930...

Page 3: ...a 7 2 3 Type key 7 2 4 Scope of delivery 7 2 5 Functions 7 3 Application use 7 3 1 Intended use 7 3 2 Improper use 8 4 Transport and storage 8 5 Installation and electrical connection 8 5 1 Installati...

Page 4: ...in grey Damage to property Safety instructions start with a signal word and are displayed without a symbol Signal words DANGER Failure to follow the instructions will result in serious injuries or dea...

Page 5: ...xchange Wear a breathing protection mask e g Half mask 3M series 6000 with filter 6055 A2 1 9 Electrical connection Do not connect products with a damaged connection cable Have the connection cable re...

Page 6: ...ation Padus MINI3 V Padus MINI3 M 1 2 3 3 4 5 5 6 6 Fig 1 Overview 1 Handle 2 Motor housing 3 Discharge connection 4 Pump housing 5 Float switch 6 Connection cable Padus MINI3 V P Drainage pump with v...

Page 7: ...ate Speed See rating plate Discharge connection G 1 IG Operating mode immersed S1 Operating mode non im mersed S3 20 2 Fluid temperature 3 40 C 37 104 F Fluid temperature short term for 3 min Max imme...

Page 8: ...ging for transport and storage Pack the pump when dry Wet or humid pumps may soften the packaging Storage conditions Maximum 15 60 C 5 140 F max humidity 90 non condensing Recommended 5 25 C 41 77 F r...

Page 9: ...be used G 1 with male thread 1 Attach the hose connection Twist the hose connection into the pressure port as far as it will go 2 Slide the hose clip over the pressure hose 3 Slide the pressure hose...

Page 10: ...n bn L phase Blue bl N neutral conductor Green yellow gn ye Earth protective earth con ductor Pump with three phase AC motor The pump is suitable for connection to a clockwise rotating field Check the...

Page 11: ...device thoroughly 7 1 Stationary wet well installation 1 Close the gate valve in the inlet and pressure pipe 2 Switch off pump Pump with a plug Pull the plug Pump firmly connected without plug Discon...

Page 12: ...ere dirt and encrustations remove the lower part of the pump housing and clean the pump interior Fig 5 Padus MINI3 V View from below 1 Place the pump on a firm surface in a horizontal position 2 Secur...

Page 13: ...r silted clogged Shut down the pump remove it and clean it 4 Float switch not operational The float switch must be able to move freely Pump starts up but does not supply fluid 1 Pressure pipe discharg...

Page 14: ...following points Hand over these products at designated certified collection points only Observe the locally applicable regulations Please consult your local municipality the nearest waste disposal s...

Page 15: ......