8 Problems, Causes and Solutions

Problem

Pump does not run

Pump runs but does not pump

Pump does not pump evenly

Pump vibrates and is noisy

Motor overheats
motor cut-out activates

Cause

no power

motor safety switch activated

Incorrect direction of rotation

pipe or pump components blocked by
foreign body

air in inlet pipe

inlet pipe too narrow

valve not sufficiently open

air in the pump

foreign body in the pump

pump not properly fixed to the base

bearing damaged

one phase interrupted

pump sluggish:

foreign body

bearing damaged

ambient temperature too high

Solutions

check fuses, cables and connections

Eliminate motor overload

check direction of rotation and correct if necessary

Check and clean pipe and pump

Seal inlet pipe

fit a larger inlet pipe

open valve

bleed the pump

remove foreign body

tighten anchor bolts

consult customer services

check fuses, cables and connections

clean pump

have pump repaired by customer services

provide cooling

If the fault cannot be remedied, please contact your plumbing and heating specialist or your nearest WILO customer services or
representative.

Subject to technical alterations!

Summary of Contents for MultiVert MVI 16 Series

Page 1: ...iebsanleitung GB Installation and operating instructions F Notice de montage et de mise en service I Istruzioni di montaggio uso e manutenzione Wilo Multivert MVI 16 MVI 32 MVI 52 MVI 70 MVI 95 2 040...

Page 2: ...Fig 1 MVI 16 MVI 32 MVI 52...

Page 3: ...Fig 1 MVI 70 MVI 95...

Page 4: ...Fig 3 Fig 2 Fig 4...

Page 5: ...llation 11 6 Commissioning 11 7 Maintenance 12 8 Problems Causes and Solutions 13 F D claration de conformit CE 2 3 1 G n ralit s 14 2 S curit 15 3 Transport et stockage avant utilisation 15 4 Descrip...

Page 6: ...tlinie 98 37 EG EC Machinery directive Directives CEE relatives aux machines Elektromagnetische Vertr glichkeit Richtlinie 89 336 EWG Elektromagnetic compatability directive i d F as amended avec les...

Page 7: ...r 91 263 EWG 92 31 EWG 93 68 EWG EG Lavspenningsdirektiv 73 23 EWG med senere tilf yelser 93 68 EWG Anvendte harmoniserte standarder s rlig 1 FI CE standardinmukaisuusseloste Ilmoitamme t ten ett t m...

Page 8: ...16 16 bar 3 230 400 V 10 50 Hz 3 400 V 10 50 Hz V 18 standard motor V 1 standard motor 2900 RPM 1450 RPM see motor rating plate F IP 55 better protective systems available 1 When using a water glycol...

Page 9: ...closely Work on the pump machinery should only be carried out when the machine has been brought to a standstill 2 6 Unauthorized modification and manufacture of spare parts Changes to the pump machin...

Page 10: ...rent Adjust to nominal current of the motor in accordance with the data on the motor rating plate Y start If the motor safety switch is connected as a star or triangu lar safety circuit combination at...

Page 11: ...can reach operating temperatures 100 C Therefore exercise caution when touching the pump 7 Maintenance Before carrying out any maintenance work switch off the pump and ensure that it cannot be switche...

Page 12: ...g damaged one phase interrupted pump sluggish foreign body bearing damaged ambient temperature too high Solutions check fuses cables and connections Eliminate motor overload check direction of rotatio...

Page 13: ...rv F 36 1 4677089 wilo wilo hu Ireland WILO Engineering Ltd Limerick T 353 61 227566 F 353 61 229017 sales wilo ie Italy WILO Italia s r l 20068 Peschiera Borromeo Milano T 39 02 5538351 F 39 02 55303...

Page 14: ...ersand Verkaufspreise Abwicklung Ihrer Auftr ge Ersatzteilbestellungen mit 24 Stunden Lieferzeit f r alle g ngigen Ersatzteile Versand von Informationsmaterial T 01805 R U F W I L O 7 8 3 9 4 5 6 F 02...

Reviews: