10.1 Faults table
All incidents hereafter mentioned will have the following effect:
• Deactivation of the SBM relay (when parameterised in „available transfer“ mode).
• Activation of the SSM relay „failure transfer“ when the maximum quantity of one fault type is reached
within a 24-hour period.
• Lighting of a red LED.
Error
number
Response
time before
fault signal-
ling
Time before
consideration
of fault, after
signalling
Waiting period before
automatic restart
Max.
faults
within
24 hours
Faults
Possible causes
Remedies
Waiting
period
before reset
E001
60 s
Immediately
60 s
6
Pump is in overload condition,
defective
Density and/or viscosity of the con-
veyed liquid is too high
300 s
Pump is obstructed by particles
Dismantle the pump and replace or
clean the defective components
E004
(E032)
~ 5 s
300 s
Immediately if defecti-
ve deleted
6
Converter supply experiences
undervoltage
Check the converter terminals:
• Fault if network < 330 V
0s
E005
(E033)
~ 5 s
300 s
Immediately if defecti-
ve deleted
6
Converter supply experiences
overvoltage
Check the converter terminals:
• Fault if network > 480 V (0.55 to 7.5 kW)
• Fault if network > 506V (11 to 22kW)
0
E006
~ 5 s
300 s
Immediately if defecti-
ve deleted
6
A supply phase is missing
Check the supply
0s
E007 Immediately Immediately
Immediately if defecti-
ve deleted
No limit
The converter runs like a genera-
tor. Warning signal, pump is not
stopped
Pump veers, check tightness of the
non-return valve
0s
E010
~ 5 s
Immediately No restart
1
Pump is locked
Dismantle the pump, clean it and replace
defective parts. It may be a mechanical
failure of the motor (bearings)
60 s
E011
60 s
Immediately
60 s
6
Pump is no longer primed or is
running dry
Prime the pump by filling it (see section
9.3)
Check the tightness of the foot valve
300 s
E020
~ 5 s
Immediately
300 s
6
Motor overheats
Clean the cooling ribs of the motor
300 s
Ambient temperature exceeds
+50 °C.
The motor is designed for operation at
an ambient temperature of +50 °C
E023 Immediately Immediately
60 s
6
Motor has short-circuit
Dismantle the frequency converter
of the pump, check and replace it, if
required
60 s
E025 Immediately Immediately No restart
1
Missing phase at the motor
Check the connection between motor
and converter
60 s
E026
~ 5 s
Immediately
300 s
6
The thermal sensor of the motor
is defective or is not correctly
connected
Dismantle the frequency converter
of the pump, check and replace it, if
required
300 s
E030
E031
~ 5 s
Immediately
300 s
6
Converter overheats
Clean the cooling ribs at the rear and
under the converter as well as the fan
cover
300 s
Ambient temperature exceeds
+50 °C.
The converter is design to operate at an
ambient temperature of +50 °C
E042
~ 5 s
Immediately No restart
1
The sensor cable (4 – 20 mA) is
interrupted
Check the correct supply and the cable
connection of the sensor
60 s
E050
300 s
Immediately
Immediately if defecti-
ve deleted
No limit BMS communication time-out
Check the connection
0s
E070 Immediately Immediately No restart
1
Internal communication fault
Contact after-sales technician
60 s
E071 Immediately Immediately No restart
1
EEPROM error
Contact after-sales technician
60 s
E072 Immediately Immediately No restart
1
Problem inside converter
Contact after-sales technician
60 s
E075 Immediately Immediately No restart
1
Inrush-current relay defective
Contact after-sales technician
60 s
E076 Immediately Immediately No restart
1
Current sensor defective
Contact after-sales technician
60 s
E099 Immediately Immediately No restar
1
Unknown pump type
Contact after-sales technician
Power
off/on
63
English