background image

15

English

WILO SE 03/2016

1. General

   1.1   About this document

The language of the original operating instruc-
tions is English. All other languages of these inst-
ructions are translations of the original operating 
instructions.
These installation and operating instructions are 
an integral part of the product. They must be kept 
readily available at the place where the product is 
installed. Strict adherence to these instructions 
is a precondition for the proper use and correct 
operation of the product.
These installation and operating instructions cor-
respond to the relevant version of the product 
and the underlying safety standards valid at the 
time of going to print.
EC declaration of conformity: 
A copy of the EC declaration of conformity is a 
component of these operating instructions. 
If a technical modification is made on the designs 
named there without our agreement, this decla-
ration loses its validity.

 

2. Safety

These instructions contain important information 
which must be followed when installing and ope-
rating the pump. It is therefore imperative that 
they be read by both the installer and the opera-
tor before the circulator is installed or started up.
Both the general safety instructions in the ‘Safety 
precautions’ section and those in subsequent 
sections indicated by danger symbols should be 
carefully observed.

   2.1  Symbols and signal words used in these  

operating instructions

          Symbols

General safety symbol.

Hazards from electrical causes.

NOTE: ....

          Signal words:

DANGER! Imminently hazardous situation. Will 

result in death or serious injury if not avoided.
WARNING! Risk of (serious) injury. ‘Warning’ 

implies that failure to comply with the safety 

instructions is likely to result in (severe) per­

sonal injury.
CAUTION! Risk of damage to the pump/instal­

lation. ‘Caution’ alerts to user to potential pro­

duct damage due to non­compliance with the 

safety instructions.

NOTE: Useful information on the handling of the  
product.
It alerts the user to potential difficulties.

   2.2  Personnel qualification

The personnel installing the pump must have the 
appropriate qualification for this work.

   2.3  Risks incurred by failure to comply with the 

safety instructions
Failure to comply with the safety precautions 
could result in personal injury or damage to the 
pump or installation. Failure to comply with the 
safety precautions could also invalidate any claim 
for damages.
In particular, failure to comply with these safety 
instructions could give rise, for example, to the 
following risks:

•  the failure of important parts of the pump or ins-

tallation,

•  personal injury due to electrical and mechanical 

causes,

•  material damage.

   2.4  Safety instructions for the operator

Existing regulations for the prevention of acci-
dents must be observed.
National Electrical Codes, local codes and regula-
tions must be followed.

   2.5  Safety instructions for inspection and assembly

This appliance is not intended for use by persons 
(including children) with reduced physical, sen-
sory or mental capabilities, or lack of experience 
and knowledge, unless they have been given 
supervision or instruction concerning use of the 
appliance by a person responsible for their safety. 
Children should be supervised to ensure that they 
do not play with the appliance.

•  If hot or cold components on the product/the 

unit lead to hazards, local measures must be 
taken to guard them against touching.

•  Guards protecting against touching moving 

components (such as the coupling) must not be 
removed whilst the product is in operation.

•  Leakages (e.g. from the shaft seals) of hazardous 

fluids (which are explosive, toxic or hot) must be 
led away so that no danger to persons or to the 
environment arises. National statutory provisions 
are to be complied with.

•  Highly flammable materials are always to be kept 

at a safe distance from the product.

•  Danger from electrical current must be elimina-

ted. Local directives or general directives [e.g. 
IEC, VDE etc.] and local power supply companies 
must be adhered to.

   2.6  Unauthorised modification and manufacture of 

spare parts
Alterations to the pump or installation may only 
be carried out with the manufacturer’s consent. 
The use of original spare parts and accessories 
authorized by the manufacturer will ensure saf-
ety. The use of any other parts may invalidate 
claims invoking the liability of the manufacturer 
for any consequences.

Summary of Contents for Helix V 22

Page 1: ...la o e funcionamento tr N vod k mont i a obsluze el sv I no Paigaldus ja kasutusjuhend fi Uzst d anas un ekspluat cijas instrukcija da Montavimo ir naudojimo instrukcija hu Be p t si s zemeltet si uta...

Page 2: ...Fig 1 FIRST...

Page 3: ...Fig 2...

Page 4: ...Fig 3 Fig 6 Fig 7 Fig 5 HIGH VOLTAGE LOW VOLTAGE L1 L2 L3 W1 V2 U2 W2 U1 V1 L1 L2 L3 L1 L2 L3...

Page 5: ...A B C D E F G H J K Helix FIRST V22 PN16 PN25 PN30 130 260 215 226 300 90 DN50 125 4 x M16 4 x 14 Helix FIRST V36 PN16 170 294 240 226 320 105 DN65 145 4 x M16 PN25PN30 8 x M16 Helix FIRST V52 PN16 P...

Page 6: ...Fig 8...

Page 7: ...riate qualification for this work 2 3 Risks incurred by failure to comply with the safety instructions Failure to comply with the safety precautions could result in personal injury or damage to the pu...

Page 8: ...l oil solid or abrasive substances or materials having long fibres The manufacturer s approval is required for use to pump corrosive chemicals CAUTION Risk of explosion Do not use this pump to handle...

Page 9: ...p See pump nameplate to know the maximum operating pressure Pmax Temperature range Liquid temperatures 20 C to 120 C 30 C to 120 C if full stainless steel 15 C to 90 C Viton version for O ring and mec...

Page 10: ...G Electrical shock hazard Dangers caused by electrical energy must be excluded 7 1 Commissioning Unpack the pump and dispose of the packaging in an environmentally responsible manner 7 2 Installation...

Page 11: ...pump design it is recom mended to connect the hydraulic network and then keep out the plastic fixation links to pre vent any leakage risk 7 4 Motor connection for bare shaft pump without motor Remove...

Page 12: ...s open completely the drain priming plug and the air bleed screw Service life 10 years depending on the operating conditions and whether all requirements described in the operation manual have been me...

Page 13: ...uct NOTE The pump must not be disposed of along with household waste Further information on recycling can be found at www wilo recycling com Subject to technical alterations Defects Causes Remedies Pu...

Page 14: ...2785961 info wilo kz Korea WILO Pumps Ltd 618 220 Gangseo Busan T 82 51 950 8000 wilo wilo co kr Latvia WILO Baltic SIA 1019 Riga T 371 6714 5229 info wilo lv Lebanon WILO LEBANON SARL Jdeideh 1202 2...

Page 15: ...Pioneering for You WILO SE Nortkirchenstra e 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Reviews: