en
Installation and operating instructions • Wilo-DrainLift BOX • Ed.06/2022-10
35
4.4
Operation with frequency con-
verter
Operation on the frequency converter is not permitted.
4.5
Type key
Example:
Wilo-DrainLift BOX-32/11HD DS O
BOX
Sewage lifting unit for sewage free of faeces
32
Nominal diameter discharge connection of the installed pump
11
Max. delivery head in m
HD
HD = Pump for aggressive fluids
D
Lifting unit version:
•
E = Single-pump system
•
D = Double-pump system
S
Pump control:
•
Without = Pump with float switch
•
S = Switchgear with float switch
O
Installation type:
•
O = Floor-mounted installation
•
U = Concealed floor installation
4.6
Technical data
Overview of technical data for the various versions.
Version
BOX-
32/8E
BOX-
32/8D
BOX-
32/8DS
BOX-
32/11E
BOX-
32/11D
BOX-
32/11DS
BOX-
40/11E
BOX-
40/11D
BOX-
40/11DS
Mains connection
1~230 V/50 Hz
1~230 V/50 Hz
1~230 V/50 Hz
Power consumption [P
1
]
450 W
750 W
930 W
Rated power [P
2
]
370 W
550 W
600 W
Max. delivery head
7 m
7 m
7 m
10 m
10 m
10 m
11 m
11 m
11 m
Max. volume flow
8.5 m³/h
8 m³/h
8 m³/h
11.5 m³/h 11 m³/h
11 m³/h
14 m³/h
14 m³/h
14 m³/h
Activation type
direct
direct
direct
Operating mode
S3 25%
S3 25%
S3 25%
S3 25%
S3 25%
S3 25%
S3 20%
S3 20%
S3 20%
Fluid temperature
3...35 °C
3...35 °C
3...40 °C
Max. fluid temperature for
3 mins
60 °C
60 °C
-
Ambient temperature
3...40 °C
3...40 °C
3...40 °C
Free ball passage
10 mm
10 mm
40 mm
Gross volume
113 l
113 l
113 l
Switching volume
26 l
24 l
30 l
24 l
22 l
30 l
29 l
27 l
29 l
Cable length to plug
10 m
10 m
1.5 m
10 m
10 m
1.5 m
5 m
5 m
1.5 m
Cable length to
switchgear
-
-
10 m
-
-
10 m
-
-
5 m
Plug
CEE 7/7 (shockproof plug)
CEE 7/7 (shockproof plug)
CEE 7/7 (shockproof plug)
Discharge connection
40 mm
40 mm
40 mm
Inlet connection
110 mm (DN 100)
110 mm (DN 100)
110 mm (DN 100)
Ventilation connection
110 mm (DN 100)
110 mm (DN 100)
110 mm (DN 100)
Concealed floor installa-
tion weight
26 kg
31 kg
36 kg
28 kg
35 kg
40 kg
33 kg
45 kg
50 kg
Floor-mounted installa-
tion weight
20 kg
25 kg
30 kg
22 kg
29 kg
34 kg
27 kg
39 kg
44 kg
4.7
Scope of delivery
DrainLift BOX ... E
•
Plastic chamber with installed pipework
•
Pipework with non-return valve
•
Pump with float switch and plug
•
Pressure hose (inside diameter: 40 mm/1.5 in) incl. hose clips
•
O-ring to seal tank cover and as anti-syphon trap
•
Concealed floor installation
Summary of Contents for DrainLift BOX
Page 2: ...DrainLift BOX https qr wilo com 742...
Page 3: ...3 Chinese 4 English 26...
Page 5: ...zh CHS Wilo DrainLift BOX Ed 06 2022 10 5 1 1 1 1 2 WILO SE 2022 1 3 Wilo 1 4 Wilo 2 2 1...
Page 6: ...zh CHS 6 Wilo DrainLift BOX Ed 06 2022 10 1 2 2...
Page 8: ...zh CHS 8 Wilo DrainLift BOX Ed 06 2022 10 2 7 2 8 2 9 3 3 1 DIN EN 12050 EN 12050 2...
Page 51: ......