English
Installation and operating instructions Wilo-CronoNorm-NL, NLG
13
6.4
Permissible forces and torques on
the pump flanges
Wilo-CronoNorm-NL series
Wilo-CronoNorm-NL series (see Fig. 3 and Tab. 3)
Values in acc. with ISO/DIN 5199 - class II (1997) - Appendix B,
Family no. 2
• for installing on the cast frame without concrete casting and a
pumping temperature up to 110 °C,
or
• for installing on the cast frame with concrete casting and a pumping
temperature up to 120 °C.
Tab. 3: Permissible forces and torques on the pump flanges - Wilo-CronoNorm-NL series
Fig. 3: Permissible forces and torques on
the pump flanges - Wilo-CronoNorm-NL
series
Z
Y
X
Y
X
Z
DN
Forces F [N]
Torques M [Nm]
F
Y
F
Z
F
X
Forces F
M
Y
M
Z
M
X
Torques M
Pressure port
32
400
500
440
780
360
420
520
760
40
400
500
440
780
360
420
520
760
50
540
660
600
1040
400
460
560
820
65
820
1000
900
1580
460
520
640
940
80
820
1000
900
1580
460
520
640
940
100
1080
1340
1200
2100
500
580
700
1040
125
1620
2000
1800
3140
700
820
1000
1460
150
1620
2000
1800
3140
700
820
1000
1460
200
2160
2680
2400
4180
920
1060
1300
1920
250
2700
3340
2980
5220
1260
1460
1780
2620
300
3220
4000
3580
6260
1720
1980
2420
3560
Su
ctio
n port
50
600
540
660
1040
400
460
560
820
65
900
820
1000
1580
460
520
640
940
80
900
820
1000
1580
460
520
640
940
100
1200
1080
1340
2100
500
580
700
1040
125
1800
1620
2000
3140
700
820
1000
1460
150
1800
1620
2000
3140
700
820
1000
1460
200
2400
2160
2680
4180
920
1060
1300
1920
250
2980
2700
3340
5220
1260
1460
1780
2620
300
3580
3220
4000
6260
1720
1980
2420
3560
350
4180
3760
4660
7300
2200
2540
3100
4560