4

4.2 MHIE***/SCe-DM (Three Phase Variable 

Speed)

SCe-DM is a variable speed three phase booster 

set which is controlled with the SCe controller via 

motor mounted drives and pressure transducer. 

Once the pressure is set on the controller the 

speed of the pump will ramp up and down 

according to the demand of the system (see panel 

manual for the setting of the system pressure). 

A suction manifold mounted low water cut out 

switch protects the booster against dry running

ATTENTION! – Pumps are factory set and do 

not need any settings changing for the set 

to function. Any changes could affect the 

performance or damage the booster

4.3 MHI***/SCe-EM (Single Phase Variable 

Speed) 

SCe-EM is a variable speed single phase booster 

which is controlled with the SCe controller via 

panel mounted frequency converters and pressure 

transducer. Once the pressure is set on the 

controller the speed of the pump will ramp up 

and down according to the demand of the system 

(see panel manual for the setting of the system 

pressure). A suction manifold mounted low water 

cut out switch protects the booster against dry 

running

T260 version comes with an integrated tank, 

float switch and stand by pump. Under low water 

conditions, the booster is set for a maximum of 15 

seconds continuous flow at full speed. 

ATTENTION! – Frequency converters are factory 

set and do not need any settings changing for 

the set to function. Any changes could affect the 

performance or damage the booster

5 Installation and operation
5.1 Foundation

The pressure-boosting system is designed for 

installation on a flat concrete floor. The base 

frame is mounted on height-adjustable vibration 

absorbers as means of insulation against 

structure-borne noise.

5.2 Hydraulic Connections

The SCe booster set is connected to the mains 

water supply via a storage tank. An isolation valves 

must be installed between the tank / discharge 

manifold and the booster(as standard onm T260). 

The customer’s pipes must be installed without 

tension. Compensators with extension limiters or 

flexible connection pipes are recommended for 

this purpose in order to avoid stress at the pipe 

connections and minimise the transmission of 

system vibrations to the building installation.. All 

SCe boster sets must be fitted with the supplied 

8 litre diaphragm pressure vessel and the pressure 

must be set to the system. Once the tank is filled 

the pumps must be properly vented before use 

(Fig 1).

ATTENTION! Connections must be made 

according to local water authority regulations

WARNING! Failure to vent the pumps correctly 

can cause damage to the pumps (Fig 1)

5.3 Hygiene

The supplied pressure-boosting system meets the 

standards of current technology has been checked 

at the factory to make sure it functions correctly. 

Please remember that when used in drinking water 

applications, the complete drinking water supply 

has to be handed over to the operator in a perfect 

state of hygiene. Flushing and disinfecting is 

essential

DANGER! Contaminated drinking water is 

a health hazard! Flushing and disinfecting 

the pipes and system reduces the risk of 

impairing the quality of the drinking water. For 

information contact [email protected] or Ph: 

01283 523 0000

5.4 Electrical Connections (Fig2-3)

Please use the correct wiring diagram provided 

with the booster for connection of mains voltage. 

Pay close attention to the terminals used and that 

the correct voltage is applied. Failure to do so may 

cause damage to pump or drives and will void the 

warranty.

DANGER! The electrical connections and testing 

must be carried out by a licensed electrician and 

in accordance with locally applicable standard 

specifications.

Summary of Contents for 29992313

Page 1: ...I404 SCe_EM 29992336 COR 3MHI404 SCe_EM 29992377 COR 2MHI404 SCe_EM_T260AB 29992321 COR 2MHI405 SCe_EM 29992337 COR 3MHI405 SCe_EM 29992378 COR 2MHI405 SCe_EM_T260AB 29992322 COR 2MHI406 SCe_EM 299923...

Page 2: ...4 5 3 Hygiene 4 5 4 Electrical Connections 4 5 5 Low Water Cut Out Switch 5 5 6 Operation 5 6 Commissioning Maintenance 6 1 Commissioning 5 6 2 Maintenance 5 7 Warranty 6 8 Tables Table 1 SCe Panel F...

Page 3: ...Wilo approved spares must be used at all times For information on spares see section 10 Spares of this manual or contact spareparts uk wilo com or Ph 01283 523 000 3 Transport and Storage SCe booster...

Page 4: ...ulic Connections The SCe booster set is connected to the mains water supply via a storage tank An isolation valves must be installed between the tank discharge manifold and the booster as standard onm...

Page 5: ...0 factory set at 300 seconds oPipe fill speed 5 8 4 0 factory set at 60 oTurn pumps on 3 1 0 0 WARNING Changes made to the drives may hamper performance or cause damage to the pumps 6 Commissioning M...

Page 6: ...ulty No electrical connection to the sensor Repair the electrical connection E054 Connection partner lost Fault in the CAN connection between the switchgear and pumps Check cable connection Check acti...

Page 7: ...r has short circuit Dismantle the frequency converter of the pump check and replace it if required E025 Immediately Immediately Missing phase at the motor Check the connection between motor and conver...

Page 8: ...Connections Figure 3 EM Electrical Connections For detailed wiring diagrams see the elctrical drawings refer to the drawings in the customer pack For detailed wiring diagrams see the elctrical drawing...

Page 9: ...9 Figure 4 Low Water Cut Out Switch Setting Figure 5 General Arrangement...

Page 10: ...375 COR 2MHI402 SCe T260 29992376 COR 2MHI403 SCe T260 29992377 COR 2MHI404 SCe T260 29992378 COR 2MHI405 SCe T260 29992379 COR 2MHI406 SCe T260 Motors 4024283 MHi202 4024285 MHi203 4024287 MHi204 421...

Page 11: ...Ce EM Motors 4024283 MHi202 4024285 MHi203 4024287 MHi204 4210718 MHi205 4210722 MHi206 4024293 MHi402 4024295 MHi403 4210725 MHi404 4210732 MHi405 4210735 MHi406 4210739 MHi802 4210743 MHi803 4210747...

Page 12: ...s 4148406 MHIE205 4148412 MHIE403 4148418 MHIE406 4148412 MHIE803 4148430 MHIE1602 Vessel 2815472 8L Expansion Vessel Controls 2549490 2X16A Control Panel 2549491 3X16A Control Panel 2085909 Pressure...

Page 13: ...w Voltage Directive Electromagnetic Compatibility Directive WEEE Directive ROHS Directive As well as following harmonized standards If the above mentioned series are technically modified without our a...

Page 14: ...14...

Page 15: ...15...

Page 16: ......

Reviews: