Chapter 2
GSM Call Mode Operation
GSM tests
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
55
How to read and work with the burst ramp zoom menu
Burst constant zoom menu
This menu shows the magnification of the constant power phase of the burst.
The resolution of the vertical axis is ±5 dB of the expected RF power level of the
mobile.
To enhance the horizontal resolution, the graphic display is cut in two parts. The
upper one shows the first 280 μs of the burst, while the lower one shows the
second ‘half’ of the burst from 260 to 540 μs.
Marker
To read the exact measurement values for specific
positions, please use the display markers.
Test
Here, the 4400 tells you whether the current burst is
ok or whether it has violated any power/time template
limits.
Note:
This is important information as the violation
could have occurred in the constant power phase of
the burst. However, that part of the burst is not visible
in this menu.
Test
parameters
On this menu, only the TCH channel number and the
mobile power level may be altered.
Resolution
With the help of this selection field, you may set the
vertical resolution according to your requirements.
The possible settings are: –15 to +5 dB, –35 to +5 dB
or –75 to +5 dB.
Special
functions
Please use the softkeys to call specific test functions.
Constant Power
A simple push on this marker tab changes to the con-
stant power zoom menu.