Chapter 2
GSM Call Mode Operation
GSM tests
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
51
Phase/Frequency live display
The phase/frequency live display shows the phase deviation of the bits received
from the mobile as a function of the bit number.
Phase/Frequency results display
The phase/frequency results display shows the numeric results and the statistical
evaluation of the test.
How to read the phase/frequency test results display
The statistical evaluation of the measurement results is displayed as current,
minimum, average and maximum values. The bar displays give a graphical repre-
sentation of the test results in relation to the measurement limits.
NOTE
To get an exact reading of the values measured, please use the display mark-
ers.
NOTE
With the help of the Resolution setting, the vertical axis (the phase error) can
be rescaled. The possible settings are: ±2, ±5, ±10, ±20 or ±50 degrees.
Default is ±10°.
Shows the total number of burst measurements
used to calculate the statistical results.
Level
These values give all the RF power level received by the
4400 (in dBm).
Note:
The current MS power level, the mobile has been
commanded to use, can be seen and altered in the
“Test
parameters”
section of this menu.