Installation Instructions (cont.)
Step 2A: Adjusting Drinking Fountain Flow (Push Button)
(WODF-1 shown)
1.) Insert a standard fl at-head screwdriver into
adjustment opening on face of pushbutton,
as shown.
2.) Rotate screwdriver to adjust until
desired fl ow is achieved:
Rotate clockwise to increase fl ow.
Rotate counterclockwise to decrease fl ow.
Step 2B: Battery Operated Infrared Sensor Startup
1.)
Remove the bottle fi ller body cap on the top of the fi xture.
2.)
Open the top of the battery box and insert 4X batteries. Replace the battery box, and
check that all sensor, battery box, and valve connections are secure.
3.)
Replace the body cap once the IR sensor has completed the start-up mode.