LX4RT SERIES INSTALLATION INSTRUCTIONS

H.E. Williams, Inc.         Carthage, Missouri         www.hew.com         417-358-4065

Page 3 

PN 49090154

TRIM SERIES (LX4RTR FLANGED TRIM VERSION)

STEP 4: INSTALL GALVANIZED FIXTURE COVER 

A.  For FLANGED TRIM installation, install galvanized fixture 

cover supplied with fixture to protect from over spRay 

during ceiling finish work.  

Tape over finger holes after 

installation.

1. 

Align side flanges on fixture cover with end plate.

End Plate

Side Flange

Align

SIDE VIEW

2. 

Overlap ends of fixture covers.

STEP 5: TAPE OVER FINGER HOLES IN FIXTURE COVERS 

Tape over holes (painter’s tape)

STEP 6: FINISH CEILING TREATMENT 

Including texture and paint as required.

STEP 7: INSTALL FLANGED TRIM

 (AS REQUIRED FOR TRIM 

APPLICATION)

A.  Install and center double mitered end trim into ends of 

fixture.

5.7” end trim

Side trim

1. 

For row-mount application, cut the double mitered side trim, 

supplied with feeder fixture, in the middle between clips that 

are approximately 4” apart. Install one half of the trim into the 

fixture at the start of the row and the other half of the trim 

into the fixture at the end of the row.  Position tight against 

the double mitered end trim already installed.

Length varies by application

4” approx.

2ft max

between clips

Cut on centerline

3/4” approx.

(both ends)

DBL miter - side trim

2. 

Install 8ft side trims between the previous trims installed.  

Cut the last 8ft side trim to fit square with the half piece of 

mitered side trim at the end.  

DO NOT RECUT THE MITERED 

ENDS.

Cut to length

as required

Half piece of 

mitered side trim

 (both ends)

8ft side trim

STEP 8: INSTALL LENSES

A.  Insert one side of lens into one side of fixture housing.  
B.  Push the corner of the opposite side of the lens into place. 
C.  Continue pushing along the housing until the entire lens is 

installed.

D.  Cut final Row-Mount lens to length as required.

To remove lens, pry out starting with the 4 inch wide end.

Removal

C

B

A

 

LX4R90T CORNERS: FIXTURE LAYOUT

Corner fixture orientation follows the flow from the power  

entry end to the end of the run.

LX4R90T-JR

LX4RT-4-J

POWER 

ENTRY

LX4R90T-FL

FEEDER 

LEFT

JOINER 

RIGHT

JOINER 

LEFT

JOINER 

RIGHT

4FT 

JOINER 

LX4R90T-JR

LX4R90T-JL

SAMPLE

FIXTURE LAYOUT

VIEWED FROM ABOVE 

CEILING PLANE

LX4RT