Battery Charging:
There are two Chargers available for the BAT 003 Rechargeable Battery.
The BAT 005 Charger plugs directly into the Transmitter MIC jack to
charge the battery without removing it from the Transmitter. The
BAT 004 Charger has battery snaps, allowing the battery to be snapped
onto the Charger. NOTE: DO NOT USE SUBSTITUTE CHARGERS.
Other Chargers will not provide a full charge with the BAT 003 Battery.
To charge the battery with the BAT 005 Charger, plug the Charger cord
into the Transmitter MIC jack and plug the charger into a wall outlet.
Make sure the Transmitter is turned OFF while charging. When the unit
is charging, a red indicator light will glow on top of the Transmitter.
Charge the battery for 14 - 16 hours.
To charge the battery with the BAT 004 Charger, remove the battery
from the Transmitter and attach it to the Charger snaps. Plug the
Charger into a wall outlet and charge for 14 - 16 hours.
If you are using the BAT SYS A Extended-Capacity Battery System,
refer to the charging instructions included with the battery system.
Rechargeable Battery Care:
Ni-Cad batteries can be recharged hundreds of times if they are properly
cared for. Batteries should be charged at least once a month, even if
they are not in use. Try to let the battery drain completely before
recharging, then immediately charge it for 14 - 16 hours.
Avoid repeated short-term (1 hour or less) use followed by charging. If
battery life becomes very short (15 - 30 min.), leave the Transmitter
turned on until the battery is completely discharged and immediately
recharge the battery.
DO NOT leave the Charger plugged in once the
battery is fully charged (about 14 hours).
BAT 005 Charger with Plug
BAT 004 Charger with Snaps
7