background image

 Installation opening size: 

 

 Wiring diagram

 

 

 

Terminals 1 and 2:

 Connect    the cooler 

Terminals 3 and 4:

 Connect    fan   

Terminals 5 and 6:

 Connect the power 

.Terminals 7 and 8:

 Connect temperature sensor 

Lock switch: If the 1 or 2 is switched to the ON position,

 

can lock the settled 

control parameters. 
 

LED Status Description:

 

  The 

WORK

 light is used as working indicator lights, flashing is to indicate the 

delay  of  cooling  or  heating,  if  the  LED  is  always  on,  it  indicates  it  is  on  the 
status of cooling or heating . 
  The 

SET

  light  is  used  as  setting  indicator  lights,  if the LED  is  always  on,  it 

indicates it is on the status of setting. 

 
 

Turn on or off the thermostat:

 

When it is wired up, the state of being acquiescent is power on.   
Press RST key to switch on and off, press the RST key once on the power-off 
state to turn it on. On the power-on state, press the RST key and hold on for 
three seconds, then it will be off. 

 
 
 
 