Night Scan Chief
4.5.1.3
Remote Control(s) Board
The handheld remote control board is located in the handheld unit and is assigned unit number
three (3). The Remote Control board may generate the messages of Table 4-3:
Table 4-3. List of Remote Control Board Faults
Message
Meaning
Root Issue
Potential Causes
Err 3,07
Unrecoverable
Communicatio
n Error
The Remote Control
board has not
received
communications
from the base board
recently
Bad or improper
connection in
communications link,
or Remote Control is
not properly powered.
Check continuity of
the data lines from
the DC power cable
connector to the
Remote Control
connector. Refer to
system schematics in
section 4.4. Check to
make sure that the
base board software
is 2.6 or newer. Refer
to section 0 on how
to check software
revision level. Also
check that the shield
in the junction box
has a good electrical
connection all the
way to the frame rail.
Err 3,08
Software Fault Internally detected
error
Indicates a software
problem. Notify Will-
Burt
Revision 1
4-17