background image

Wilks

 Enterprise Inc

 

 

                                            InfraRan Instruction Manual

 

 

39

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

NORWALK, CT.

A

Assy. #

Chassis Assy.

112-0004

1
2
3

VFD Display
Display Mount
440 SEMS

312-0001
206-2102
Indirect

1
1
4

4
5
6

Upper Chassis
Rubber Mount
440 SEMS

 
206-2112
205-1021
Indirect

1
16
4

Item                             Description                                           P/N              Qty

Parts List :

 

 
 
 
 
 
 

Summary of Contents for InfraRan

Page 1: ...InfraRan is a trademark of Wilks Enterprise Inc Copyright 2004 2008 Wilks Enterprise Inc Norwalk Ct USA...

Page 2: ...2 SOFTKEY MENU OPERATIONS MAP 10 7 2 1 TOP MENU 10 7 2 2 ANALYZE MENU 10 7 2 3 RUN MENU 11 7 3 FILES MENU 12 7 4 SETUP MENU 12 7 4 1 DIAG MENU 13 7 4 2 CLOCK MENU 14 7 43 ANALYSIS MENU 14 7 4 4 LOG M...

Page 3: ...18 1 ANALOG OUTPUT 28 19 0 SPECIFICATIONS 29 20 0 TROUBLESHOOTING 30 21 0 SERVICE AND CUSTOMER SUPPORT 32 FIGURE 1 INFRARAN OPTICAL SYSTEM WITH 16CM CELL 4 FIGURE 2 INFRARAN OPTICAL SYTEM WITH 6M CEL...

Page 4: ...n the instrument is received examine the container for damage unpack the container and check its contents 1 InfraRan Analyzer 1 Charger AC Adapter InfraRan Interconnect Cable 1 Sampling Hose Particula...

Page 5: ...e window of a tubular single pass transmission cell or a folded path multipass cell A portion of the energy is absorbed by the sample The infrared beam passes through an exit window then through an op...

Page 6: ...ly 4 more hours the detector voltage varies approximately linearly with temperature during the warm up period The linear fit should not be counted as being appropriate for a long time Each time the In...

Page 7: ...Wilks Enterprise Inc InfraRan Instruction Manual 6 Figure 3 InFraRan Controls and Connections...

Page 8: ...the inlet and outlet it is advised that an external pump be used It is not recommended that an external pump be attached to the internal pump as this may cause pressure or a vacuum differential that c...

Page 9: ...d be taken to ensure that the strap is in good condition and properly used Occasionally check the strap hooks for cracks and that the metal safety clip is intact and properly operating Check the strap...

Page 10: ...previous menu item The up arrow forwards to the next menu item The right arrow enters a space Keypad Backlight option This button by default selects Survey fast or Analyze normal mode The Survey fast...

Page 11: ...lyze Menu REZERO Prompts user INSTALL ZERO FILTER Press ZERO Softkey Timer countdown 30 seconds to introduce fresh air Timer countdown 30 seconds to zero instrument Display zero voltage of detector RU...

Page 12: ...ions LOG ON indicates that the logging operation is currently off Pressing LOG ON will change the softkey to LOG OFF and display a LOG ON indication on the top left of the display Pressing the LOG OFF...

Page 13: ...Press ENTER to accept changes ERASE Prompts user to delete file press ENTER key to erase data in current file ESCAPE cancels erase operation ESCAPE Returns to prior menu 7 4 Setup Menu DIAG Diagnosti...

Page 14: ...gs containing information on current calibrated gas s ESCAPE Returns to prior menu 7 4 1 Diag Menu VERIFY Prompts calibration standard concentration Press ENTER to start verification Prompts user to i...

Page 15: ...ar Month Date with keys on keypad TIME Set Hour Minute Second with keys on keypad ESCAPE Returns to prior menu 7 43 Analysis Menu LOG Settings for logging functions on off status mode and interval DIS...

Page 16: ...from 1 second to 1 minute ESCAPE Returns to prior menu Note The analyzer does not average readings over the time period set in interval Instead the analyzer will take a snapshot of the concentration...

Page 17: ...ctory Set k Factory Set Range Factory Set Scale Factor Factory Set Temp Comp Factory Set High Alarm User Select Low Alarm User Select ID Number User Select When all the calibration values have been en...

Page 18: ...rcent of charge on analyzer battery BRIGHT Selectable display brightness from 25 to 100 set to 25 for best battery life ESCAPE Returns to prior menu Note Setting the pump or alarms either on or off ef...

Page 19: ...this mode is enabled The fast mode is intended for detecting leaks or hot spots The measurements are not signal averaged In this mode the display is considerably noisier than in the normal mode but r...

Page 20: ...YOU ARE READY TO SAMPLE 12 0 USB Driver Installation 1 Plug in the USB cable from the host computer to the InfraRan USB mini B port 2 The host computer will come up with a dialog box noting that it h...

Page 21: ...n Manual 20 From the Control Panel select the SYSTEM icon Click on the Hardware Tab and then click on the Device Manager Button Confirm that an additional COM port has been added the host computer It...

Page 22: ...ow Control With the InfraRan USB cable plugged in and the analyzer on press ANALYZE then RUN After the analyzer has started the RUN cycle a continuous stream of data should be now displayed on hyperte...

Page 23: ...Select Capture Text a Name File b Hit Start 14 2 Using the Excel Spreadsheet Download Note Before using the spreadsheet program the cheapcomm program available on the CD must be loaded first A Open th...

Page 24: ...en C Change the COM port number to the correct port that the InfraRan USB port is assigned Click on the current COM port assignment in the Enter Serial Port box Change the COM number in the fx formula...

Page 25: ...sing the Download then Files softkeys on the InfraRan followed by ENTER on the keypad G The Excel program should now display Transfer In Progress in the Download report button After the transfer is co...

Page 26: ...analysis functions external to the InfraRan analyzer Or to perform external logging functions The data stream 13MAR06 12 29 11 2 7553 0 0 0077 2 7535 20 67 123 Field 1 2 3 4 5 6 7 8 1 Date DDMMMYY 2 T...

Page 27: ...Wilks Enterprise Inc InfraRan Instruction Manual 26 16 0 Input Output and Power Connectors Figure 8 Analyzer Connections...

Page 28: ...nalyzer on it s side remove the 4 retaining screws and the battery door 2 Loosen the two thumb screws on the battery cover Swing the cover out and lift out the cover from it s retaining slot 3 Press i...

Page 29: ...ata string It is generated by an eight bit digital to analog converter DAC The correspondence between the analog signal and the digital value is determined by the Range setting found in the Setup Cali...

Page 30: ...99 gas exchange Measurement Cycle Display updated every 1 5 sec Source Pulsed thin film element Communications RS 232 DB 9 connector Communications protocol 9600 baud 8 N 1 Concentration Alarm Two le...

Page 31: ...severe mechanical shock optical components source detector gas cell or electronic components have failed Useful measurements will not be possible The analyzer must be returned to Wilks Enterprise for...

Page 32: ...de Press Control Pump If Pump Off is highlighted press the key under Pump On to turn the pump on You should be able to hear the pump and feel vacuum at the inlet and pressure at the outlet If the pump...

Page 33: ...u are recommended to contact your local representative or dealer first If the analyzer was purchased direct or if there are problems that are unanswered by the local representative or you have a techn...

Page 34: ...Ran Instruction Manual 33 ITEM DESCRIPTION QTY P N 1 2 3 4 5 6 Parts List 206 2139 205 1036 206 2140 205 1035 205 1034 1 1 1 1 1 1 FILTER HOLDER FILTER GASKET PLUG ADAPTER SWAGELOK NUT SWAGELOK PORTAD...

Page 35: ...EM DESCRIPTION QTY P N Parts List 1 2 3 4 5 6 7 8 Wand Handle Handle Grip Sample Tube 1 4 Inch Port Adapter Swage Nut 1 4 NPT To 1 4 Swage Adapter Filter Soft Nylon Tubing 1 1 1 2 2 1 1 4 Ft 206 2124...

Page 36: ...Wilks Enterprise Inc InfraRan Instruction Manual 35...

Page 37: ...Wilks Enterprise Inc InfraRan Instruction Manual 36...

Page 38: ...e Gore Battery Vent Screw In Plug Painted 832 x 1 2 Flathead Screw 1 4 20 x 1 Caphead Screw 1 4 20 Large Pattern Flat Washer 1 4 20 Jam Nut Right Side Panel Left Side Panel H Gasket 50 In Length Batte...

Page 39: ...Wilks Enterprise Inc InfraRan Instruction Manual 38...

Page 40: ...on Manual 39 NORWALK CT A Assy Chassis Assy 112 0004 1 2 3 VFD Display Display Mount 440 SEMS 312 0001 206 2102 Indirect 1 1 4 4 5 6 Upper Chassis Rubber Mount 440 SEMS 206 2112 205 1021 Indirect 1 16...

Page 41: ...400 1008 1 2 3 4 5 6 7 8 9 10 11 Signal Conditioning Board Assy CPU Board Accessory Board CPU To Accessory Board Cable VFA Cable CPU to S C Board Cable Connector Plate Assy 4 40 x 1 2 SEMS 4 40 x 3 8...

Page 42: ...Wilks Enterprise Inc InfraRan Instruction Manual 41 Parts List Item Desc P N Qty 12 13 14 4 40 x 1 4 SEMS 4 40 x 1 4 Flathead Screw Battery Compartment 206 2110 10 8 1...

Page 43: ...000 4 5 1995 Surge Immunity Power Leads IEC 61000 4 6 1995 Conducted Immunity Power and I O Leads IEC 61000 4 11 1994 Voltage Dips and Interupts The Technical Construction file is maintained at Wilks...

Reviews: