MAINTENANCE
Description
3
Inspections
The motor of this model is equipped with brushes. When they are worn the need to be replaced. To replace
the brushes see below.
Remove the worn brush by unclipping and pulling out. Replace by inserting the new brush and re clipping.
NOTE: Change both motor brushes at the same time.
Please note that regular maintenance of the system ensures general durability.
Periodic maintenance of the filters
The maintenance intervals recommended periodic maintenance are listed below.
GROUP TO CHECK
FREQUENCY OF CONTROL
OPERATIONS TO DO
Decanting container door
When checking the filters
Empty an blow with compressed
air
Spark arrestor
When the extraction is low
Blow with compressed air
Micro filter cartridge
About every 300-500 hours
Change
Carbons
When the expelled air has bad
smell
Change
The filters should be replaced after 2 or 3 cleans.
The filters, when replacing, must be disposed of according to local disposal regulations.
For the replacement of the filters is carried out as described previously.
Defects