Specifications 

Housing: 

16 Ga. Rolled steel with stainless steel hardware 

Finish: 

Flat black powder coat 

Mounting: 

Two fully adjustable L brackets 

Reflector: 

Polished Everbright aluminum 165° 

Sockets: 

EM-22L:   Four positive locking medium Bi-Pin G13 
EM-42L:   Four positive locking medium Bi-Pin G13 
EM-44L:   Eight positive locking medium Bi-Pin G13 

Input Voltage: 

100-240VAC

Input Current: 

EM-22L:   0.30A Max 
EM-42L:   0.57A Max 
EM-44L:   1.14A Max 

Frequency: 

50-60Hz

Power Factor: 

0.99 

Power Consumption: 

EM-22L:   30W 
EM-42L:   60W 
EM-44L:   115W 

Operating Temperature: 

14° F to 95° F (-10° C to 35° C) 

Humidity: 

0-95% non-condensing

Power Cord: 

6

’ 16/3 SOW with PowerCON 1 in and male Edison 

Power Connections: 

Neutrik PowerCON 1input and output 

Power Linking: 

EM-22L:   30 units at 120VAC 
EM-42L:   15 units at 120VAC 
EM-44L:   10 units at 120VAC 

Lamps: 

EM-22L:   Two Wildfire SableLED L15T9/BLB UV LED Tube Lamps 
EM-42L:   Two Wildfire SableLED L30T9/BLB UV LED Tube Lamps 
EM-44L:   Two Wildfire SableLED L30T9/BLB UV LED Tube Lamps 

Peak Wavelength: 

365nm 

Beam Angle: 

120° 

Lamp Life: 

40,000 Hrs 

Dimensions: 

EM-22L:   4.25”/10.79cm High  x  5.00”/12.44cm Wide  x  27.37”/69.52cm Long 
EM-42L:   4.25”/10.79cm High  x  5.00”/12.44cm Wide  x  51.37”/130.48cm Long 
EM-44L:   4.25”/10.79cm High  x  6.50”/16.51cm Wide  x  51.37”/130.48cm Long 

Weight: 

EM-22L:   7.60 lbs./3.44kg. 
EM-42L:   15.35 lbs./6.96kg. 
EM-44L:   18.20 lbs./8.25kg. 

IP Rating: 

IP-20 Indoor use 

Warranty: 

Three Year Parts and Labor 

Standard Equipment: 

Wildfire SableLED UV LED Tube Lamps, Adjustable Mounting Brackets, 

Power Cord, 

PowerCON Power Out 

Cable 

Connector

 

Optional Accessories: 

Twenty Clamp (147-021) 
Safety Cable (147-002) 
Floor Mount (147-006) 
T-Bar Ceiling Mount (147-003)

Summary of Contents for EffectsMaster EM-22L

Page 1: ...Operation Manual Ultraviolet LED Lighting Fixtures EM 44L EM 42L EM 22L...

Page 2: ...placement 6 Cleaning 6 Troubleshooting 6 Diagrams 7 Isometric Line Views EM 22L 7 Isometric Line Views EM 42L 8 Isometric Line Views EM 44L 9 Exploded View Part List EM 22L 10 Exploded View Part List...

Page 3: ...L FLUORESCENT LAMPS IN THIS FIXTURE WARNING THIS FIXTURE EMITS ULTRAVIOLET RADIATION UV AT A PRIMARY WAVELENGTH OF 365NM AVOID EYE AND SKIN EXPOSURE AT DISTANCES SHORTER THAN 3 3 1m DO NOT LOOK INTO T...

Page 4: ...ing EM 22L 30 units at 120VAC EM 42L 15 units at 120VAC EM 44L 10 units at 120VAC Lamps EM 22L Two Wildfire SableLED L15T9 BLB UV LED Tube Lamps EM 42L Two Wildfire SableLED L30T9 BLB UV LED Tube Lamp...

Page 5: ...ture on the floor for footlight applications Contact Wildfire or your local distributor for pricing T Bar Ceiling Mount These brackets enable you to mount your Effects Master fixture to the t bars in...

Page 6: ...sure that both ends of the lamp are installed correctly neither end of the lamp should move in the socket Cleaning For best performance the reflector lamps and protective lens should be kept free of d...

Page 7: ...Isometric Line Views EM 22L 7 Diagrams 24 125 27 375 5 00 4 25...

Page 8: ...Isometric Line Views EM 42L 8 Diagrams 48 125 51 375 5 00 4 25...

Page 9: ...Isometric Line Views EM 44L 9 Diagrams 48 125 51 375 6 50 4 25...

Page 10: ...1 017 Screw SM PHL PH 8 x 3 8 18 8 SS QTY PART PART NAME 12 2 121 033 Kepnut 4 40 18 8 SS 13 4 121 003 Screw M PHL PH 4 40 x 3 8 18 8 SS 14 2 104 004 01 Bracket Lens Retaining Optional Lens Kit 15 1 1...

Page 11: ...002 Lamp LED SableLED T9 BLB 48 30W QTY PART PART NAME 12 2 124 016 01 Lens Clear UVT 4 x 4 3 4 Optional Lens Kit 13 1 106 053 Receptacle PowerCON 1 Power OUT NAC3MPB 1 14 1 106 051 Receptacle PowerC...

Page 12: ...ment 107 003 1 8 Cord Power Black 16 AWG 6 108 004 8 9 Socket Lamp G13 Base 121 017 16 10 Screw SM PHL PH 8 x 3 8 18 8 SS 141 002 4 11 Lamp LED SableLED T9 BLB 48 30W 106 051 1 12 Receptacle PowerCON...

Page 13: ...Schematic LED Series EM 22L 13 BLACK WHITE POWER SWITCH AC OUTPUT AC INPUT GREEN...

Page 14: ...Schematic LED Series EM 42L 14 BLACK WHITE POWER SWITCH AC OUTPUT AC INPUT GREEN...

Page 15: ...Schematic LED Series EM 44L 15 BLACK WHITE POWER SWITCH AC OUTPUT AC INPUT GREEN...

Page 16: ...am Diameter Meters Peak UV A Irradiance W cm2 5 1 5 2 1 0 3 0 5 2 0 6 1 0 3 0 9 1 4 4 0 1 2 1 9 5 0 1 5 2 4 6 0 1 8 2 9 7 0 2 1 3 3 8 0 2 4 3 8 Model EM 42L Distance in Feet Meters 17 3 5 2 130 0 34 6...

Page 17: ...od is to notify Wildfire of any suspected defect to obtain a return authorization number and to return the product freight and insurance prepaid to the following address Wildfire Service 2908 Oregon C...

Page 18: ...2908 Oregon Ct Suite G1 Torrance CA 90503 P 310 755 6780 800 937 8065 F 310 755 6781 wildfirelighting com mail wildfirelighting com 2017 Wildfire Inc c 215 011 03...

Reviews: