Disassembly / Reassembly
Pump Disassembly
Tools Required:
•
3/16" Hex-Head Wrench
•
7/16" Wrench or Socket for
Rubber-Fitted
•
5/16" Wrench or Socket
•
3/8" Wrench O-Ring Pick
•
3/16" Rod or Equivalent)
CAUTION:
Before any maintenance or repair is attempted, the compressed air
line to the pump should be disconnected and all air pressure allowed to bleed
from pump. Disconnect all intake, discharge, and air lines. Drain the pump by
turning it upside down and allowing any fluid to flow into a suitable container.
Wetted flushing of parts may be required prior to handling.
The Wilden model P .025 is an air-operated, double-diaphragm pump with all
wetted parts of aluminum, stainless steel or Hastelloy
®
. The single-piece center
section, consisting of center block and air chambers, is molded from acetal or
polypropylene. The air valve is manufactured of acetal or polypropylene.
All O-rings used in the pump are of special materials and should only be
replaced with factory-supplied parts.
To expedite parts ordering, please find an exploded view of the P .025 model at
the back of this manual.
PLEASE read all directions before starting disassembly.
NOTE:
Replace worn parts with genuine Wilden parts for reliable performance.
Step 1
Before actual disassembly is started, turn
pump upside down and drain all liquid
trapped in the pump into a suitable
container. Be sure to use proper caution if
liquid is corrosive or toxic. Mark each liquid
chamber to its respective air chamber for
easy alignment during reassembly.
Step 2
Using a 3/16" hex-head wrench, loosen
the four manifold bolts. Remove the top
and bottom manifolds.
Step 3
Inspect both manifolds, manifold O-rings,
and valve balls. If swelling, cracking or
other damage is apparent, these parts
must be replaced with genuine Wilden
parts.