WIL-10187-E-05
8
P8 Clamped Plastic
SECTION 5
P8 PLASTIC
RUBBER-FITTED
Ship Weights……Polypropylene 34 kg (75 lb)
PVDF 43 kg (95 lb)
Air Inlet……………………..……..13 mm (1/2")
Inlet…...…………………...…………51 mm (2")
Outlet………………...………………51 mm (2")
Suction Lift…………………….7.4m Dry (24.4')
8.6 m Wet (28.4')
Disp. per Stroke
1
……...…........2.8 L (0.73 gal)
Max. Flow Rate……………591 lpm (156 gpm)
Max. Size Solids…………………6.4 mm (1/4")
1
Displacement per stroke was calculated at 4.8
bar (70 psig) air inlet pressure against a 2.1 bar
(30 psig) head pressure.
Example:
To pump 379 lpm (100 gpm) against
a discharge head of 2.1 bar (30 psig) requires 4.1
bar (60 psig) and 104 Nm
3
/h (66 scfm) air
consumption.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
P8 PLASTIC
TPE-FITTED
Ship Weights……Polypropylene 34 kg (75 lb)
PVDF 43 kg (95 lb)
Air Inlet……………………..……..13 mm (1/2")
Inlet…...…………………...…………51 mm (2")
Outlet………………...………………51 mm (2")
Suction Lift……………………5.9 m Dry (19.3')
8.6 m Wet (28.4')
Disp. per Stroke
1
……...…........2.8 L (0.73 gal)
Max. Flow Rate……………583 lpm (154 gpm)
Max. Size Solids…………………6.4 mm (1/4")
1
Displacement per stroke was calculated at 4.8
bar (70 psig) air inlet pressure against a 2.1 bar
(30 psig) head pressure.
Example:
To pump 371 lpm (98 gpm) against
a discharge head of 2.1 bar (30 psig) requires
4.1 bar (60 psig) and 107 Nm
3
/h (68 scfm) air
consumption).
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
DIMENSIONAL DRAWING
PERFORMANCE