S U G G E S T E D O P E R A T I O N & M A I N T E N A N C E
S U G G E S T E D I N S T A L L A T I O N
WILDEN PUMP & ENGINEERING, LLC
8
WIL-11112-E-01
NOTE: In the event of a power failure, the shut-off
valve should be closed, if restarting of the pump is not
desirable once power is regained.
AIR-OPERATED PUMPS: To stop the pump from
operating in an emergency situation, simply close
the shut-off valve (user-supplied) installed in the air
supply line. A properly functioning valve will stop the
air supply to the pump, therefore stopping output. This
shut-off valve should be located far enough away from
the pumping equipment such that it can be reached
safely in an emergency situation.
AIR INLET
PRESSURE
GAUGE
AIR SUPPLY
RETURN TO TANK
RELIEF VALVE
(SET TO 250 PSI)
DISCHARGE
LINE
SHUT-OFF VALVE
SHUT-OFF VALVE
SHUT-OFF VALVE
PRESSURE OR
VACUUM GAUGE
SUCTION
LINE
FLEXIBLE
CONNECTION
SHUT-OFF
VALVE
AIR SHUT-OFF VALVE
COMBINATION
FILTER & REGULATOR
NEEDLE VALVE
MUFFLER
NOTE:
This illustration is a generic representation
of an air-operated double-diaphragm pump.