Circulation connection 
 

In order to operate the combi tank with a hot water circulation, a 

circulation connection attachment

 from Wikora is to be 

installed between the tank and the circulation pipe. The circulation connection attachment is supplied as a pre-assembled unit, 
and consists of one T-piece with integrated circulation dip lance

 

made of stainless steel and a DHW mixing valve to prevent 

scalding. The attachment is to be installed according to the preceding connection scheme. Any other connection method is not 
acceptable and compromises the function of the combi tank. It is recommended to set the DHW mixing valve at 45-55°C. 
 
 
In general, a circulation pipe involves high stand-by losses. For this reason, we recommend: 

 

The use of a circulation pump which is dependent  on time and temperature 

 

The adequate insulation of the pipes 

 

Equipping the circulation pipe with a check valve 

6  Commissioning 

  Before  putting  into  operation,  the  entire  system  should  be  flushed  through.  Particles  in  the  system  compromise  the 

operating reliability.  

  Fill the heating system slowly with water and vent all the air. 

  Open the 

cold water stop valve 

and all hot water nozzles. The hot water heat exchanger is full when water leaks out 

of all hot water nozzles. Then close all nozzles again. 

  Start-up the heating system. 

  While the System is heating up, water will leak out of the safety valve.

 

 

Before  the  handover  of  the  system  to  the  end  user/owner,  the  plumbing  contractor  should  ensure  that  the 
system is tested to full load, controls are set and that pipe work and connections are without leaks. 

Afterwards, 

the end user has to be instructed in the operation and handling of the tank, as well as the system. The instruction must 
to be documented in the installation and maintenance record.,

 

  Please note that the operation and lifetime of the system depend decisively on a regular maintenance.  

7  Maintenance and wear parts 

Regular maintenance increases the lifetime and operation reliability of the system.  Decalcification at regular intervals may be 
necessary in highly calcareous water areas.  

Attention – only valid for heating tanks with hot water supply.

 

A  chemical  decalcification  can  be  carried  out  by  a  specialist  using  an  approved  decalcifier  and  taking  the  appropriate 
precautions. 
1. 

The safety valve protects the tank against excess pressure. The functional capacity must be checked at regular intervals 
by venting. If an expansion vessel is used, the safety valve is not, or only rarely, required. Over a longer period of time 
therefore, it can become blocked and not function when needed. 

2. 

If there is a danger of freezing, the DHW tank should be permanently heated or completely emptied. 

3. 

A  damp  cloth  is  sufficient  to  clean  the  outer  parts.  Please  avoid  using  any  abrasive  or  solvent  cleaning.

Summary of Contents for WIKOSOL 805

Page 1: ...maintenance record must be entirely completed and the user has to be instructed accordingly Efficient operation can only be guaranteed if the instructions of this manual are followed Warranty does no...

Page 2: ...alve outlet in width It may not have more than 2 bends and should not be longer than 2 m If for any compelling reasons 3 bends or a length up to 4 m are required then the entire exhaust line must be d...

Page 3: ...80 1802 1520 1020 700 290 830 290 980 1020 700 290 1845 1520 Wikosol 805 2 790 990 160 1650 1880 1802 1520 1020 700 290 830 1490 290 1085 980 1020 700 290 1845 1520 Chart 1 W Tilting dimension Connect...

Page 4: ...aterial DHW heat echanger W St 1 4404 Material tank S235JR Corrosion protection buffer Internal bare external coated with corrosion proof lacquer Performance tank fully loaded 65 C HV 70 C HW 45 C CW...

Page 5: ...he tank immersion sleeve and sensor rail The tank s venting and draining facilities must have the appropriate dimensions and be correctly installed The installation company is responsible for the corr...

Page 6: ...ozzles again Start up the heating system While the System is heating up water will leak out of the safety valve Before the handover of the system to the end user owner the plumbing contractor should e...

Page 7: ...has been modified through the installation of externally supplied parts or through irregular professional maintenance Subject to our general terms and conditions Legal warranty 2 years Guarantee year...

Page 8: ...operation and maintenance Place Date Customer Installer Signature Signature Place of installation Name ZIP Code Place Street Phone Tank model Serial number Date of invoice In the case of reclamation...

Reviews: