EN
14347811.01 07/2019 EN/DE
34
WIKA operating instructions model TGT73 (Ex)
Electrical data
Long-term stability of
electronics
< 0.3 % of full scale/a
Temperature error of
electronics
< 0.3 % of full scale value/10 K (in overall
temperature range)
Warm-up time
≤ 5 min
Electrical connection
Via angular connector, 180° rotatable,
max. 1.5 mm², cable protection, M20 x 1.5 cable
gland, cable outer Ø 7 ... 13 mm, incl. strain relief
Designation of connection
terminals dependent on
the output signal version
Terminal
Type
1
2
3
4
5
6
Variant I
4 ... 20 mA
GND
I+
reserved
reserved
reserved
reserved
Variant II (Ex)
4 ... 20 mA
GND
I+
reserved
reserved
reserved
reserved
Variant III
0 ... 10 V
GND
UB+
Uout
reserved
reserved
reserved
For further specifications see WIKA data sheet TV 17.10 and the order
documentation.
10. Specifications