19
EN
ADPR1X914112.01 09/2020 EN/DE
WIKA operating instructions, model F2812
9. Specifications
9. Specifications
Model F2812
Rated force F
nom
N
50, 100, 150, 200, 300, 500, 600, 1,000
Relative linearity error d
lin
±0.5 % F
nom
Relative reversibility error v
±0.5 % F
nom
Relative span in unchanged mounting position
b
rg
±0.25 % F
nom
Relative deviation of zero signal d
S, 0
±2 % F
nom
Temperature effect on the zero signal TK
0
≤ ±0.2 %/10 °C
Temperature effect on the characteristic value
TK
C
≤ ±0.2 %/10 °C
Limit force F
L
120 % F
nom
Breaking force F
B
200 % F
nom
Material of the measuring body
Stainless steel
Rated temperature range B
T, nom
-10 … +60 °C
Service temperature range B
T, G
-20 … +80 °C
Input resistance R
e
700 ±30 Ω
Output resistance R
a
700 ±5 Ω
Insulation resistance R
is
≥ 5,000 MΩ/DC 100 V
Output signal (rated characteristic value) C
nom
2.0 ±10 % mV/V
Electrical connection
Measuring cable ∅ 3 x 3,000 mm
Voltage supply
without amplifier
DC 10 V (max. 15 V)
with cable amplifier
DC 12 … 28 V for output 0(4) … 20 mA
DC 0 … 10 V
Protection (acc. to IEC/EN 60529)
IP65
Weight in kg
0.1
9.1 Approvals
Logo
Description
Country
EU declaration of conformity
■
EMC directive
■
RoHS directive
European Union
EAC
■
EMC directive
Eurasian Economic
Community