Remote Control

 

 

Maintenance

 

 
All  the  CPD8000  functions,  even  the  ACF  running 
command, 

can be executed from an external computer

 

through serial communication (RS232C), which enables it 
to be integrated in an automatic calibrating system. 
A programming example is given in the user’s manual. 

 

 
The  CPD8000  is  delivered  with  all  the  operating 
instructions,  consumables  and  tools  allowing  its  general 
maintenance.  No  other  maintenance  is  necessary  if  the 
standard  is  used  in  accordance  with  the  routine 
instructions  described  in  the  manual.  Usual  recalibrations 
need only take place every 3 years. 

 

Calibration 

 

CE Compatibility

 

 
All  the  CPD8000  standards  are  delivered  with  a  gauge 
calibration certificate  issued  as  standard  by  the  COFRAC 
accredited  Degranges  &  Huot’s  laboratory  (accreditations 
2-1033  and  2-1129),  which  assures  the  user  that  the 
presented calibration results are unbiased. 
The COFRAC calibration guarantees the traceability of the 
measurements done by the CPD8000 to the National and 
International Standards. 
 
The  calibration  is  operated  in  accordance  with  the  RM 
aero 802.22 recommendation and takes into account: 
-  The Kn specific coefficient determination 
-  The ACF calibration control 
The  uncertainty  calculation  presented  in  the  certificate 
respects  the  ISO  TAG4  and  EAL  recommendations  and 
shows  the  enlarged  uncertainty  of  the  CPD8000  with  a 
coefficient k = 2. 
 
It takes into account the CPD8000’s intrinsic measurement 
errors,  the  uncertainty  of  the  reference  means  as  well  as 
the  influence  of  the  environment  conditions,  the  pressure 
control  of  the  CPD8000’s  metrological  performances  and 
the  calculation  of  its  measurement  uncertainty  by 
comparison with a reference standard.  

 

 
The  CPD8000  complies  with  the  following  European 
directives and norms: 

-

 

n° 89/336/CEE Electromagnetic Compatibility Directive 
dated  May  3

th

,

 

1989  modified  by  the  n°  92/31/CEE 

directive  dated  May  12

th

,  1992  and  the  n°  93/68/CEE 

directive dated July 22

th

, 1993 

-

 

n°  73/23/CEE  Low  Tension  Directive  dated  February 
19

th

,  1973  modified  by  the  n°  93/68/CEE  directive 

dated July 22 

th

,

 

1993 

-

 

EN  50082-1  Ed.92  norm  (Emission  with  the 
89/336/CEE directive) 

-

 

EN  55022  B  Class  Ed.  87  norm  (Immunity  with  the 
89/336/CEE  directive),  EN  61010  norm  (Safety  rules 
for  the  use  of  measuring,  regulating  and  laboratory 
electric instruments with the 73/23/CEE directive) 

 

Option 

 
By using a special adaptation kit, it is possible to use the 
gauge  head  model  of  the  CPD8000-G(Head  model  110, 
111, 410 and 710) with the CPD8000-A. Those heads can 
be used to works only in gauge mode but allows extending 
the range capability of the CPD8000-A up to 50 MPa. 

Conclusion

 

 

 

 
Due  to  its  design  and  its  performances,  the  CPD8000 
primary  digital  standard  is  unique  in  the  world.  The 
operations  with  the  balance  do  not  necessitate  a  bell  to 
make the vacuum and masses to load. 
Associated to an automatic controller, the CPD8000 allows 
performing  fast  calibrations,  without  having  to  break  the 
vacuum  between  each  pressure  point,  with  a  high 
metrological reliability. 
This  instruments  is  used  by  our  more  faithful  customer 
who  are  National  Laboratories,    Meteorology,  the  R&D 
laboratories, sensor manufacturers, airway companies … 
 

 

 

 

 
 
 

 
 
 

Desgranges & Huot 

 

56 Rue des Ecoles 

 

93303 Aubervilliers – France 

 

Tel : +33 1 4839 8300 

 

Fax: +33 1 4833 6590 

 

E-Mail : 

[email protected]

 

 

www.dh-budenberg.com 

 

Page 8 of 8 

 

 

 

 

                  Desgranges & Huot WIKA Data Sheet CPD8000 04/2012 

Summary of Contents for cpd8000-g

Page 1: ...ea CPD8000 is a worldwide exclusivity combining two high level technologies Best available piston cylinder assemblies whose effective area A is perfectly known High accuracy force cell which measure t...

Page 2: ...only Dedicated to gauge measurements the force cell is let at the atmospheric pressure CPD8000 A Absolute and gauge mode Versatile measurer the force cell is placed in reference chamber which can be a...

Page 3: ...the force transmitted to the measuring force cell by the pressure is perfectly and fully vertical then without alteration It has been created to make sure that the rotating noises be less important th...

Page 4: ...se masses can also be used to run an external calibration 5 The Environment Monitoring Module EMM In order to determine whether it is worthy to use the ACF the CPD8000 is equipped with an Environment...

Page 5: ...olatile memory of the CPD8000 Kn of the piston cylinder assembly Sensitivity of the measuring force cell Nk Normal gravity gn Local gravity gl Pressure distortion coefficient of the piston cylinder as...

Page 6: ...kg Pure gas A06 5 Pa 5 MPa 5 Pa 5 bar kg Pure gas G01 0 1 Pa 100 kPa 0 1 Pa 0 1 bar kg Pure gas G02 0 2 Pa 200 kPa 0 2 Pa 0 2 bar kg Pure gas G03 0 5 Pa 500 kPa 0 5 Pa 0 5 bar kg Pure gas G04 1 Pa 1...

Page 7: ...ity hysteresis linearity and 3 year stability Typical uncertainty researched for a 200 kPa range k 2 U 0 8 Pa 1 E 5 P Dimension L x W x H 530 x 400 x 320 mm Measurement fluid Dry and non corrosive cle...

Page 8: ...rmances and the calculation of its measurement uncertainty by comparison with a reference standard The CPD8000 complies with the following European directives and norms n 89 336 CEE Electromagnetic Co...

Reviews: