WIKA operating instructions models TR10-0, TC10-0 (FM, CSA)
14503941.01 11/2021 EN/DE/FR/ES
21
EN
IP ingress protection per IEC/EN 60529
First index number Degree of protection / Short description
Test parameters
Degrees of protection against solid foreign bodies (defined by the 1st index number)
5
Dust-protected
Per IEC/EN 60529
6
Dust-tight
Per IEC/EN 60529
Degrees of protection against water (defined by the 2nd index number)
4
Protected against splash water
Per IEC/EN 60529
5
Protected against water jets
Per IEC/EN 60529
6
Protected against strong water jets
Per IEC/EN 60529
7
1)
Protected against the effects of temporary
immersion in water
Per IEC/EN 60529
8
1)
Protected against the effects of permanent
immersion in water
As agreed upon
1) Ingress protections, describing temporary or permanent immersion, on request
Standard ingress protection of model Tx10-0 is IP65.
The specified degrees of protection apply under the following conditions:
■
Use of a suitable thermowell (without suitable thermowell: IP40)
■
Use of a suitable cable gland
■
Use of a cable cross-section appropriate for the gland or select the appropriate cable
gland for the available cable
■
Adhere to the tightening torques for all threaded connections
11.1 Model TR10-0
Measuring element
Type of measuring element
Pt100, Pt1000
1)
Measuring current
0.1 ... 1.0 mA
Validity limits of the class accuracy in accordance with EN 60751
Class B
Wire-wound
-196 ... +600 °C [-321 ... +1,112 °F]
Thin-film
-50 ... +500 °C [-58 ... +932 °F]
Class A
2)
Wire-wound
-100 ... +450 °C [-148 ... +842 °F]
Thin-film
-30 ... +300 °C [-22 ... +572 °F]
Class AA
2)
Wire-wound
-50 ... +250 °C [-58 ... +482 °F]
Thin-film
0 ... 150 °C [-32 ... +302 °F]
1) Pt1000 only available as a thin-film measuring resistor
2) Not with 2-wire connection method
For further specifications see WIKA data sheet TE 61.01 and the order documentation.
11. Specifications