background image

5

 

| Switch Design 

Wieland Electric GmbH | BA001108 (Rev. A) | 01/2017 

11 

Note!  

Make sure the screws dimensions are suitable for 
use with the wall mounting plate. 

Do not completely tighten the screws into the wall. A 
final adjustment may be needed before fully securing 
the wall mounting plates on the wall. 

11.

 

Align the wall mounting plate over the screws on 
the wall. 

12.

 

Install the wall mounting plate on the screws and 

slide it forward to lock in place. 

13.

 

Once the device is installed on the wall, tighten 
the screws to secure the device. 

 
 

 
 
 

5.6

 

Description of the Front-Panel 

On the front panel some LEDs can be found which indicate the power and network status.  

LED Definition 
LED 

Color 

Description 

 

 

 

P1 

Green 

On 

Power input 1 is active 

Off 

Power input 1 is inactive 

P2 

Green 

On 

Power input 2 is active 

Off 

Power input 2 is inactive 

P-Fail 

Red 

On 

Power input 1 or 2 is in-

active 

Off 

Power input 1 and 2 are 

active or no power input 

Loop 

Red 

On 

Loop is detected 

Off 

No loop detected 

 
 

 

NOTE 

Wall mount installation 

Summary of Contents for wienet LMS 16-W

Page 1: ...wienet LMS 16 W Ethernet switch USER MANUAL Doc No BA001108 Updatet 01 2017 Rev A...

Page 2: ...ain the right to modify the information This customer document describes all the hardware units and functions known at the present time De scriptions may be included for units which are not present at...

Page 3: ...7 Features 7 4 Contents of Package 7 5 Switch Design 8 5 1 Basic dimensions of the switch 8 5 2 Ordering code 8 5 3 Mounting and demounting recommendations 9 5 4 Mounting and demounting on a DIN rail...

Page 4: ...at the beginning 1 3 Presentation of safety relevant information Information that warns of personal injury or property damage are emphasized by safety instructions Please read this information carefu...

Page 5: ...of the duty to observe the restrictions concerning the utilization of radio de vices at petrol stations in chemical plants or in the course of blasting works in which explo sives are used Switch off...

Page 6: ...2 Dual Power Input wienet LMS 16 W redundant power input design is with power reserve protection to prevent the switch device broken by wrong power wiring When one of the power inputs fails P Fail LED...

Page 7: ...dicators P1 P2 P Fail and Loop help you diagnose immediately 3 7 Features Provides 16 x 10 100Base TX ethernet ports with 4 PoE injectors of RJ 45 connector Supports 12 to 48 V DC power input Provides...

Page 8: ...the switch 5 2 Ordering code Ordering code is shown in the table below Name Order code Features interfaces LMS 16 W 83 040 1334 0 16x ETH 10 100 TX wieland w LMS 16 P 1 P 2 P F a i l L o o p 1 5 2 6 3...

Page 9: ...sors Between data cables and cables with reticular tension of 230 V 50 Hz sufficient space min 50 mm should be kept A certain space must be kept before the cables for connecting or disconnecting singu...

Page 10: ...vided screws for later use 4 Align the wall mounting plates on the rear side The screw holes on the device and the mounting plates must be aligned see the following illustration 5 Secure the wall moun...

Page 11: ...screws and slide it forward to lock in place 13 Once the device is installed on the wall tighten the screws to secure the device 5 6 Description of the Front Panel On the front panel some LEDs can be...

Page 12: ...utput 7 DC POE power if POE is equipped 8 DC POE power if POE is equipped Ethernet connector Pin assignment RJ45 Plug EIA TIA 568B 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 W...

Page 13: ...er supply is required to main tain a UL60950 panel listing The chassis ground screw terminal should be tied to the panel or chassis ground A redundant power configuration is supported through a second...

Page 14: ...inal block over the terminal block receptor on the switch 8 Insert the terminal block and press it in until it is flush with the terminal block receptor 9 Tighten the screws on the terminal block to s...

Page 15: ...chapter 5 1 Weight 670 g Housing material Metal Module earth screw and by snapping onto earthed DIN rail Caution must be with low impedance Shock and vibration Shock IEC60068 2 27 Vibration IEC60068...

Page 16: ...ply in a range from 12 to 48 V DC Note Select the proper UTP cable to construct user network Use Unshielded Twisted Pair UTP or Shielded Twisted Pair STP cable for RJ 45 connections 100 Category 3 4 o...

Reviews: