WiebeTech HP-LT User Manual Download Page 4

WiebeTech LLC 

 

H o t P l u g   U s e r ’ s   M a n u a l

 

  - 4 -         

 

 

5. 

You will now establish a connection between HotPlug’s gray output line cord and the computer’s 
original source of power.  This is done one of two ways, depending on how the computer is 
plugged in.   
 

If the computer is plugged into a multi-outlet surge protector or power strip 

This is by far the most common configuration you will encounter.  First, unplug any unneeded 
devices from the power strip from which the computer is currently receiving power.  This will 
reduce power draw and ensure there is a receptacle available for use with HotPlug.  Next, 
connect the gray output line cord into the power strip.  After you have plugged the output line cord 
into the power strip, HotPlug’s red LED (output power indicator) will light.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

If the computer is plugged directly to a wall outlet 

This is less common.  You will need to use the Plug Capture Device (PCD) to create the 
connection.   

A) 

Install the PCD on the free plug end of the output line cord.  

B) 

Next, carefully pull the computer’s A/C plug about 1/8-inch out 
from the wall.  Do not pull it more than 1/8-inch or the power 
connection may be broken.   

C) 

Slide the PCD’s end tab between the two power conductors in the plug and between the 
wall outlet and the plug.  Push down on the PCD until it makes electrical connection and 
mechanically seats on the plug.  HotPlug’s red LED should light, indicating that a solid 
electrical connection is established.   

 

 

 
 
 
 
 
 
 
 
 
 
 

(Red color indicates path of computer’s power) 

1/8” 

NOTE:  You  will  not  be  able  to 
use  PCD  with  European  plugs 
that have insulated prongs.   
 

UPS 

HotPlug 

Summary of Contents for HP-LT

Page 1: ...antly reroutes power of a target device to a UPS for transport Use the same HotPlug to seize more than one computer at a scene Table of Contents Accessories 2 Mouse Jiggler 2 HotPlug Control Panel 2 H...

Page 2: ...at product HotPlug Control Panel A Input Power power coming from the new power source such as a portable UPS B Power Switch Turns HotPlug unit on off Glows when HotPlug is connected to new power sourc...

Page 3: ...hat a second receptacle on the same circuit is available on the new power source i e a duplex outlet 4 Plug the gray output line cord into the HotPlug unit receptacle labeled OUT YOU SHOULD NOW ASSUME...

Page 4: ...e cord into the power strip HotPlug s red LED output power indicator will light If the computer is plugged directly to a wall outlet This is less common You will need to use the Plug Capture Device PC...

Page 5: ...ource 8 You are now ready to transfer the computer s source of power As with step 5 this process varies slightly depending on the specific configuration If the computer is plugged into a multi outlet...

Page 6: ...AT THE PLUG Be careful not to touch yourself other people or any objects with the plug while you move it After establishing electrical contact between the plug and the receptacle on the UPS you may di...

Page 7: ...e plug or outlet is inaccessible through conventional capture then you must slit the cable with the cable sheath slitter After you have carefully cut the sheath back enough to where the wires are expo...

Page 8: ...igh impact case material Watertight Lockable Status Indicators Power on and armed indicators are discernible at a glance Red indicator lights show which receptacles are powered Yellow indicator light...

Reviews: