Wido IHEAT1 User Manual Download Page 8

10. Technical Specification

-8-

Model

Rated 

Voltage

Rated 

Input

Max. Rated 

Heat Input

Gas Pressure

(Regulator)

Air 

Flow

Maximum Gas

Consumtpion

Fuel Type

IHEAT1

ZSG151

220-240V~50Hz

220-240V~50Hz

220-240V~50Hz

30W

15kW

0.5bar

300m3/h

750m3/h

750m3/h

1.11kg/h

2.2kg/h

2.9kg/h

G30-I3

B/P

IHEAT2

ZSG301

80W

30kW

1.5bar

G30-I3

B/P

IHEAT3

ZSG401

80W

40kW

1.5bar

G30-I3

B/P

Maximum allowed size of gas cylinder: 10kg.

Gas Supply Circuit Drawing

Electric Circuit Drawing

Item  

Parts name 

Flame failure protector 

Electromagnetic valve 

Adjustment valve 

Gas nozzle  

Burner Assembly 

Thermocouple  

Thermostat  

Summary of Contents for IHEAT1

Page 1: ...ng and using this ar cle Retain them for future reference and if you are passing this product to a third party always make sure this documenta on is included Gas Space Heater Model IHEAT1 IHEAT2 IHEAT...

Page 2: ...he appliance or on the packaging 1 Explanation of symbols 2 Intended Use This appliance is designed as an auxiliary temporary hea ng for non domes c indoor spaces It must be used in well ven lated spa...

Page 3: ...alist To avoid danger faulty power cords must only be replaced by the manufacturer customer service or a similarly quali ed person using an equivalent cable Switch o the appliance and always disconnec...

Page 4: ...verhea ng may cause re The appliance should never be poin ng towards the gas cylinder This heater is not to be used for hea ng habitable areas of domes c premises for use in public buildings refer to...

Page 5: ...on prevent the gas leakage and poten al carbon monoxide poisoning and re danger inducted by gas leakage A gas rate adjustment valve is installed in this product the heat input can be regulated to ful...

Page 6: ...ly Press the ON OFF power switch 9 to ON posi on 6 Open the gas supply valve on the gas cylinder 7 Use the right hand to push the aluminium handspike of the ameout protector 6 and keep for 10 seconds...

Page 7: ...obstruct the fan Straighten all fan blades Heater will not ignite No spark at igni on needle Spark cable disconnected Incorrect spark plug gap Distance between electrode and burner too large Any repa...

Page 8: ...50Hz 30W 15kW 0 5bar 300m3 h 750m3 h 750m3 h 1 11kg h 2 2kg h 2 9kg h G30 I3B P IHEAT2 ZSG301 80W 30kW 1 5bar G30 I3B P IHEAT3 ZSG401 80W 40kW 1 5bar G30 I3B P Maximum allowed size of gas cylinder 10...

Page 9: ...e every use You can prepare the test solu on ahead in the small garden sprayer Inspect the gas hose regularly for any signs of wear or damage Keep the heater in clean working order Inspect and clean t...

Page 10: ...material In observance of European Direc ve 2012 19 EU on waste electric and electronic equipment and its implementa on in accordance with na onal law electric equipment that have reached the end of t...

Page 11: ...11...

Page 12: ...STRIAL HEATER V1 09 2018 Batch Number If problems are encountered with this appliance please quote your order number product code IHEAT1 IHEAT2 or IHEAT3 and below batch number every me you contact cu...

Reviews: