5.Troubleshooting 

If the ADSL Loop Extender can’t work well, please compare to the Table5 

and Table6 to find out the problems.     

Table 6    AEC-B1P Troubleshooting 

Problem Description

 

Possible Reason

 

Suggested Resolution

 

Equipment does not work 

after power-up. Status 

LED is OFF. 

Power supply cable is 

not correctly 

connected. 

Check power supply cable connection. 

Power indicator flashes. 

Power output 

circuitry fails. 

Check whether the connection is shorted. 

Or check whether the connection between 

Extender and Modem is OK. 

Output is OK but the 

Extender does not work. 

Power output cable 

connection is error or 

short. 

Correct the power output connection or 

check cable. Or check whether the 

distance between DSLAM, Extender, 

Modem is proper. 

 

 

 

 

 

 

 

 

Summary of Contents for AEC-B1P

Page 1: ...du Sichuan China Tel 8628 84207501 Fax 8628 84209696 Web Site http www widearea com cn ADSL Loop Extender and ADSL Loop Extender Power Supply AER800 1P 2P AEC B1P Installation Manual Version 004 Pleas...

Page 2: ...of the product read this manual thoroughly before use Please keep this manual handy for ease of reference The contents of this document may be changed in the future without prior notice This booklet...

Page 3: ...sion of Widearea Tel 8628 84207501 8628 84207506 Contents 1 Unpack 3 2 Technical Features 3 3 Installation Environment 4 4 Installation Steps 6 5 Troubleshooting 11 6 Techical Assistance Customer Serv...

Page 4: ...material Inspect equipment for shipping damage including bent or loose hardware and broken connectors If equipment was damaged in transit contact supplier Product list AER800 1P AER800 2P one AEC B1P...

Page 5: ...ng 0 5A 3 Installation Environment 1 the actual lines connecting of equipment Figure 1 actual lines connecting L1 The signal twist pair connecting ADSL Loop Extender to DSLAM L2 The signal twist pair...

Page 6: ...ce demand Min Max kfeet km L1 CO Extender 450 1260 5 0 13 0 1 5 4 0 L2 Extender CPE 200 900 2 0 9 5 0 5 3 0 L CO Extender CPE 800 1600 6 5 22 5 2 0 7 0 24 AWG twist pair The demand about resistance an...

Page 7: ...junction cabinet or on the pole at the middle locality The Power Supply is installed either at CO or at CPE with remote supply The details about ADSL Loop Extender and Power Supply installation are as...

Page 8: ...Connector Wiring Diagram Three core power cord without plug used for DC48V power input no polarity Three core power cord with plug used for AC110 240V power input Power output 155V power output cable...

Page 9: ...accessories include power cord for AC 110V AC220V or DC 48V Connect it to the AC 110V AC220V or DC 48V power source with good connection To easy the installation DC power source connection is no polar...

Page 10: ...ng point Figure 6 AER800 1P 2P installing Outdoors Just as the structure above the ADSL Loop Extender is fixed in the wire rope or in the wall with a fixity Connect the cables Wiring sockets on front...

Page 11: ...cables are connected correctly and enclosure is securely installed power up the system The ADSL Loop Extender will work in 20 seconds after power is supplied stead Attention a A and B represent A and...

Page 12: ...scription Possible Reason Suggested Resolution Equipment does not work after power up Status LED is OFF Power supply cable is not correctly connected Check power supply cable connection Power indicato...

Page 13: ...are not connected properly Correct the cable connection Line quality is worse between CO and CPE side Change good quality cable There is telephone before the splitter on CPE side Discard the telephone...

Page 14: ...nternet is slow frequent off line problem Affection of computer hardware failures system failures and virus Check computer or take with PC testers and so on to deal with The parallel cable at CPE side...

Reviews: