Aquatronic 2 ultra
0
fAulT fiNDiNG
Problem/Symptom Cause
Action/Cure
5.
Shower varies
from normal
temperature to cold
during use.
6.
Pressure relief
device has operated
(water ejected from
PRD tube).
5.1
Water pressure has
dropped below minimum
required.
6.1
Blocked showerhead.
6.2
Twisted/blocked
flexible shower hose.
6.3
Showerhead
not removed while
commissioning.
5.1.1
Wait until the water pressure resumes to
normal.
6.1.1
Clean sprayplate and then fit a new PRD.
6.2.1
Check for free passage through hose.
Replace hose if necessary and then fit new PRD.
6.3.1
Fit new PRD. Commission unit with
showerhead removed.
note:
Identify cause of operation before fitting new PRD unit.
When fitting a new PRD, follow the commissioning procedure.
It is advised all electrical maintenance/repairs to the shower
should be carried out by a suitably qualified person.
In the unlikely event of a fault occurring please contact triton customer service.
do not remove the shower from the installation.