Selection Of Output Connection: 

 

Please choose wires with suitable diameter/cross section based on the current rating. Please refer to the following table for the  information of 

some frequently used wires. Using red wires to connect the (+) terminals and black ones for (-) terminals is highly  recommended. 

 

AWG 

CROSS SECTION(mm

2

Max.Current(A) 

UL1015(600V 105

°

C) 

10 

5.262 

35 

12 

3.309 

22 

14 

2.081 

12 

16 

1.309 

 

Suggested Battery Capacity:

 

1.   Batteries larger than shown may be charged, it just takes more time to reach full charge. 

2.   Questions about suitable charging currents should be referred to the battery manufacturer and published data. 

 

Model 

Suggested Battery capacity 

 CC-1215W 

60-120Ah 

 

Fault Finding:

 

 

Status 

Possible Reasons 

Ways to Eliminate 

 
 
 
 
 

 

No output 
voltage 

 

 

Power switch is not set to ON(-) 

 

Set the power switch to 
ON(-) 

 

Wrong polarity of the battery 
connection (output fuse open) 

 

 

Replace the fuse 

 

Wrong selection of the 115/230Vac 
switch 

Repair  required.  Please 
send it back to us or any 
of our distributors 

 

Output voltage 
is too low 

 

Wrong selection of the 115/230Vac 
switch 

Choose the correct input 
voltage range through the 
115/230Vac switch 

Can't achieve 
the FLOAT 
(green light) 
stage after 
long period 
of charging 
operation 

Batteries are aging or faulty 

Replace the batteries 

 
 

The battery has a load on it 

 
 

Remove the load or seek 
advice on ways to adjust 
the charger to suit the load 

If you still cannot solve a problem, please consult Wialki Electronics as below. 

 

 

WARNINGS: 

Explosive gases may be present while charging batteries. prevent flames and sparks. 

Provide adequate ventilation during charging. 

Disconnect the supply before making or breaking the connections to the battery.                  

Only charge lead acid type batteries 

 
 
Cautions: 

Temperature of the case will be high during the charging operation. 

For safety only use a properly grounded outlet 

The charger should be fixed firmly at its place of operation or be mounted on a holding rack for extra support.  

Reserved space for built in should be at least (325*145*55) L*W*H 

 

 

Wialki Electronics 

Unit 7  13-15 Harvard Way 

Canning Vale  WA  6155 

Ph:  (08) 9455 2245  Fax:  (08) 9455 2137 

Web:  

www.wialkielectronics.com.au

 

Email:  

[email protected]

  