background image

ONE YEAR LIMITED WARRANTY & 

THREE YEAR WARRANTY ON COMPRESSOR

 

This WHYNTER product is warranted to the original owner, purchased from an authorized Whynter dealer within the 48 

U.S. continental states, for one year from the original purchase date against defects in material and workmanship under 

normal residential usage. Should your WHYNTER product prove defective within one year from the date of purchase, 

contact Whynter’s Customer Support team with the serial number and proof of purchase to make a warranty claim. A 

Return Authorization number must be issued before returning any parts or products. Parts or products received without 

a Whynter issued Return Authorization number will be refused. Under this warranty, Whynter will repair or replace any 

parts found defective with new or remanufactured parts or exchange the defective product with a new, refurbished, or 

remanufactured product at our discretion. All defective products and parts covered by this warranty will be repaired or 

replaced on a mail-in basis to Whynter’s Service Center. This warranty is not transferable. After the expiration of the 

warranty, the cost of labor and parts will be the responsibility of the original owner.

The compressor of portable air conditioners is warranted for an additional two years after the one year limited warranty 

expires from the date of purchase. 

Return freight is prepaid by Whynter within two months of purchase. After two months to one year, the customer will be 

responsible for the return freight cost to Whynter’s Service Center. Please package the product carefully in its original 

packaging  to  avoid  damage  in  transit.  Whynter  is  not  responsible  for  damage  resulting  from  shipper  mishandling  or 

improper packaging. Please retain the original box and packaging materials. 

THIS WARRANTY DOES NOT COVER: 

Acts of God, such as fire, flood, hurricanes, earthquakes and tornadoes.

Improper power supply such as power surge, low voltage, defective household wiring or inadequate fuses.

Use in commercial or industrial applications.

Damage, accidental or otherwise, to the product while in the possession of a consumer not caused by a defect in

material or workmanship.

Damage caused by consumer misuse, tampering, lack of maintenance or failure to follow the care and special

handling provisions in the instructions.

Damage to the finish of the case, or other appearance parts caused by wear.

Damage caused by repairs or alterations to the product by anyone other than authorized by the manufacturer.

Removal, Replacement Packaging, Freight and Insurance cost for the warranty service.

Products sold AS IS or from an unauthorized reseller.

Products that have had their serial numbers removed or defaced.

DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES

CUSTOMER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR 

REPLACEMENT AS  PROVIDED HEREIN.  CLAIMS  BASED  ON IMPLIED WARRANTIES,  INCLUDING  WARRANTIES  OF 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD 

ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR. WHYNTER SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR  

INCIDENTAL DAMAGES  SUCH  AS  PROPERTY  DAMAGE  AND INCIDENTAL EXPENSES  RESULTING  FROM  ANY BREACH 

OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW 

THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE- QUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION 

OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WRITTEN WARRANTY 

GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.

The warranty, product contents and specifications are subject to change at any time without notice; please refer to 

www.whynter.com for the most current information. 

Please retain the original proof of purchase.

To register your warranty, please visit www.whynter.com and fill out the online

Warranty Registration form. Please be sure to include a copy of your purchase invoice.

To obtain service or information, contact Whynter LLC via email at

[email protected] or call 866-WHYNTER (866-949-6837).

Copyright © 2017 Whynter LLC

www.whynter.com

4

.

2

0

.2017-1

200

Summary of Contents for ARC-14SH

Page 1: ...DITIONER WITH HEATER MODEL ARC 14SH Instruction Manual Congratulations on your new WHYNTER product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference ...

Page 2: ... ACCESSORIES 6 IDENTIFICATION OF PARTS 7 OPERATING YOUR AIR CONDITIONER 8 INSTALLATION INSTRUCTIONS 9 10 AIR FILTERS INSTALLATION 11 OPERATION INSTRUCTIONS 12 13 WATER DRAINAGE 14 REMOTE CONTROL 15 CARE AND MAINTENANCE 16 TECHNICAL DATA 17 TROUBLESHOOTING 18 19 WARRANTY INFORMATION 20 ...

Page 3: ...l provide the performance and reliability that we stand for Please keep this user manual in a safe place for future reference DISPOSAL This symbol on the product or its packaging indicates that the appliance cannot be treated as normal domestic trash but must be handed in at a collection point for recycling electric and electronic appliances Your contribution to the correct disposal of this produc...

Page 4: ... or wet areas Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances Do not repair disassemble and or modify the unit by yourself Always turn off the portable air conditioner when cleaning the air filter and transporting Do not turn this unit on and off by plugging and unplugging Always use the ON OFF switch Transport the unit in an uprig...

Page 5: ...ency of the portable air conditioner At the end of each season all water must be drained from the unit and filter s must be cleaned before storage THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED OPERATING CONDITION MODE ROOM TEMPERATURE COOL Higher than 64 F DRY Higher than 60 F HEAT Higher than 45 F Your portable air conditioner is supplied with a Leakage ...

Page 6: ...ors 4 pieces Window slider kit 1 set Cover 2 pieces Remote control 1 piece Optional Intake filter sold separately 1 piece Optional 3M Antimicrobial filter sold separately 1 piece Storage Cover 1 piece Carbon Filter 1 piece IDENTIFICATION OF ACCESSORIES Note Please visit whynter com for optional accessories information ...

Page 7: ...7 P a g e IDENTIFICATION OF PARTS Front 1 Air vent 2 Control panel Rear 3 Evaporator air intake air filter 4 Air intake hose 5 Air exhaust hose 6 Casters 7 Drain plug 8 Power cord ...

Page 8: ...e in the unit If the internal reservoir becomes full the warning light and the STOP light will come on and the unit will stop until the water is drained Timer Temperature Set Control Adjusts set thermostat temperature and timer The display temperature is the set temperature NOTE This unit is capable of displaying set temperature in Fahrenheit or in Celsius To convert from one to the other press an...

Page 9: ...tional When the unit is operating in dehumidifying or fan only mode installation of the exhaust hose is optional 1 Expand each end of the exhaust and intake hoses about 6 2 Install the hose connectors onto the exhaust and intake hoses by turning clockwise 3 Align the tab cut outs of each of the hose connectors to the tabs on the air exhaust and air intake at the rear of the unit and snap in place ...

Page 10: ...additional security measures may be needed 1 Open the window approximately 5 2 Adjust the length of the window slider to the same length and width of the opening of the window Cut the window slider if necessary to fit the length of your window 3 Insert the fixture through the back grooved side of the window slider hose cut out Line up the fixture with the 4 screw holes and tighten the fixture with...

Page 11: ...months 11 P a g e AIR FILTERS INSTALLATION Your Whynter portable air conditioner is equipped with a washable Pre Filter and an Activated Carbon Filter The washable Pre Filter removes large particles such as dust pet hair and dander The Activated Carbon filter is designed to remove smoke and other odors It is recommended you replace the Activated Carbon filter every 2 3 months or as needed Follow t...

Page 12: ...en the compressor is running the sound difference between each fan speed is not very noticeable DEHUMIDIFYING MODE In this mode the air conditioner dehumidifies the room the compressor will activate intermittently depending on the ambient temperature and the fan speed is set to Low To activate dehumidifying mode press the Mode Control button until the indicator illuminates When switching between f...

Page 13: ...elayed switch ON or delayed switch OFF of the air conditioner The time hours delay can be set enabled and disabled The timer is adjustable between 1 24 hours SETTING SWITCH OFF TIMER With the air conditioner operating in any function mode press the Timer Control button Then set the desired time delay OFF hours by pressing the or buttons When the delay time set has elapsed the air conditioner switc...

Page 14: ...the unit the air conditioner stops running and the RED Stop light illuminates The Stop light indicates that the water condensation needs to be drained manually Manual Drainage 1 Turn off the unit 2 Carefully roll the unit to a drain location or position a flat container dish or optional drain bucket accessory sold separately under the drain area of the lower drain port 3 Remove the drain cover and...

Page 15: ...f the remote control by sliding if off Strictly adhere to the polarity signs on the bottom of the battery housing close the flap once the batteries have been inserted Other appliances in the same room controlled by a remote control TV radio stereo etc may cause interferences Electronic and fluorescent lamps may interfere with the signal transmissions between the remote control and the air conditio...

Page 16: ...formation or visit whynter com for a list of optional accessories WARNING Never operate the air conditioner without the pre filter in place CLEANING THE AIR CONDITIONER Always switch off the air conditioner and disconnect the plug from the power supply outlet before cleaning the air conditioner Use a soft damp cloth to wipe the body of the unit Never use harsh chemicals oil based products detergen...

Page 17: ...ng the air conditioner on early instead of waiting until the hottest point of the day will allow the unit to be more effective The air conditioner will not have to work as hard to cool the room down and maintain the set temperature 3 Reduce heat sources Direct sunlight televisions computers and other heat generating appliances work against the air conditioner by introducing heat into the space Clo...

Page 18: ...oling The room temperature is outside of the operational tolerances of the unit The Cooling mode is not on The compressor has not turned on yet because of its time delay The set temperature is too high The internal water reservoir is full This unit is designed to work in ambient temperatures of 64 F to 95 F Press the MODE button until the COOL light is shown on the display Give the compressor 3 mi...

Page 19: ...s to be drained too often The humidity in the area may very high Possible loose connection Remove the intake hose if the outside humidity is high or it is raining Contact Whynter Service Department Fan speed cannot be changed Fan speed differences are not very noticeable The fan speed difference is not very noticeable when the compressor is on Try setting the unit to Fan only mode you should be ab...

Page 20: ...s Use in commercial or industrial applications Damage accidental or otherwise to the product while in the possession of a consumer not caused by a defect in material or workmanship Damage caused by consumer misuse tampering lack of maintenance or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear ...

Reviews: