INSTALLATION INSTRUCTIONS

Location

The air conditioner should be placed on a hard and level surface strong enough to support the
unit. The unit has casters and it should only be rolled on smooth, flat surfaces. Use caution
when rolling on carpet surfaces. Do not attempt to roll the unit over objects.
Never place any obstacles around the air inlet or outlet and allow at least 20 inch of clearance
for efficient air-conditioning.

Exhaust hose Installation

When you use this air conditioner unit, hot air must be exhausted out of the room to complete

the air exchange of the condenser. When the unit is operating in DEHUMIDIFYING or FAN only

mode, no exhaust is required.

1. Pull out about 6” of one end of the hoses.

2. Attach the hose connectors to the hoses by turning clockwise.

3. Align the slots on the hose connector to the tabs on the air intake / outlet and snap the

hose to the unit.

4. Only extend the exhaust hoses to the necessary length. We do not recommend

extending the exhaust hose more than 9' long. If you are interested in purchasing an

additional 5’ exhaust hose please contact [email protected] for retail sales information.

Summary of Contents for ARC-14S

Page 1: ...CONDITIONER co Instruction Manual MODEL ARC 14S Congratulations on your new WHYNTER product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this...

Page 2: ...ACCESSORIES 6 IDENTIFICATION OF PARTS 7 OPERATING YOUR AIR CONDITIONER 8 INSTALLATION INSTRUCTIONS 9 10 AIR FILTERS INSTALLATION 11 OPERATION INSTRUCTIONS 12 13 WATER DRAINAGE 13 REMOTE CONTROL 14 CAR...

Page 3: ...provide the performance and reliability that we stand for Please keep this user manual in a safe place for future reference DISPOSAL This symbol on the product or its packaging indicates that the app...

Page 4: ...unit by yourself Always turn off the portable air conditioner when cleaning the air filter and transporting Do not turn this unit on and off by plugging and unplugging Always use the ON OFF switch Tr...

Page 5: ...ing efficiency of the portable air conditioner At the end of each season all water must be drained from the unit and filter s must be cleaned before storage THE MANUFACTURER DISCLAIMS ANY RESPONSIBILI...

Page 6: ...g e IDENTIFICATION OF ACCESSORIES IMAGE ACCESSORY NAME QUANTITY Exhaust hose 2 pieces Fixture 2 pieces Screws 8 pieces Hose connector 4 pieces Window slider kit 1 set Cover 2 pieces Remote control 1...

Page 7: ...7 P a g e IDENTIFICATION OF PARTS Front 1 Air vent 2 Control panel Rear 3 Evaporator air intake air filter 4 Air intake hose 5 Air exhaust hose 6 Casters 7 Drain port 8 Power cord...

Page 8: ...in the unit If the internal reservoir becomes full the warning light and the STOP light will come on and the unit will stop until the water is drained Timer Temperature Set Control Adjusts set thermo...

Page 9: ...you use this air conditioner unit hot air must be exhausted out of the room to complete the air exchange of the condenser When the unit is operating in DEHUMIDIFYING or FAN only mode no exhaust is re...

Page 10: ...ow or sliding door it will cause the window or sliding door not to be properly closed and locked Additional security measurements maybe needed 1 Open window approximately 5 2 Adjust the length of the...

Page 11: ...is designed to remove smoke and other odor It is recommended you replace the Activated Carbon filter every 2 3 months or as needed Follow the steps below to install the filters WARNING NEVER OPERATE...

Page 12: ...an Speed button In cooling mode the difference in noise level between the 3 fan speeds is not very noticeable when the compressor is on Try setting the unit to Fan only mode you should be able to hear...

Page 13: ...e air conditioners may make sounds that are not familiar to you The sounds listed below are normal Noise reflecting off hard surfaces such as a floor or wall can make the sounds seem louder than they...

Page 14: ...ransmissions between the remote control and the air conditioner Remove the batteries if the remote control is not used for long periods INSTALLING BATTERIES Only use two AAA 1 5V Batteries in the remo...

Page 15: ...2 3 months or as needed WARNING Never operate the air conditioner without the filter in place CLEANING THE AIR CONDITIONER Always switch off the air conditioner and disconnect the plug from the power...

Page 16: ...supply 115v 60Hz Maximum power input 1250 Watts Maximum input 10 8 Amps Dehumidifying capacity 101 Pts Day Thermostat 61 F to 89 F Refrigerant R 410A Air flow max 360 m3 Hour Fan speeds 3 H M L Exhau...

Page 17: ...onal tolerances of the unit The Cooling mode is not on The compressor has not turned on yet because of its time delay The set temperature is too high The internal water reservoir is full This unit is...

Page 18: ...oling or another air conditioner The unit is very noisy The unit is not level The surface underneath the unit is uneven Low power voltage Make sure the unit is on hard level and stable surface Move th...

Page 19: ...e caused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage...