background image

 

ONE YEAR LIMITED WARRANTY &  

THREE YEAR WARRANTY ON COMPRESSOR 

 

This  WHYNTER  portable  air  conditioner  is  warranted,  to  the  original  owner  within  the  48 
continental  states,  for  one  year  from  the  date  of  purchase  against  defects  in  material  and 
workmanship under normal use and service. Should your WHYNTER portable air conditioner 
prove  defective  within  one  year  from  the  date  of  purchase,  return  the  defective  part  or  unit, 
freight prepaid (within two months of purchase; after two months to one year, customer will be 
responsible for freight cost to Whynter’s service department), along with an explanation of the 
claim  to  Whynter  LLC.  Please  package  the  portable  air  conditioner  carefully  in  its  original 
packaging  material  to  avoid  damage  in  transit.  Please  retain  the  original  box  and  packaging 
material.  Under  this  warranty, Whynter  will  repair  or  replace  any  parts  found  defective.  This 
warranty is not transferable. After the expiration of the warranty, the cost of labor and parts will 
be the responsibility of the original owner of the unit.  

 

THIS WARRANTY DOES NOT COVER: 

  Acts of God, such as fire, flood, hurricanes, earthquakes and tornadoes. 

  Damage, accidental or otherwise, to the air conditioner while in the possession of  

a consumer not caused by a defect in material or workmanship; 

  Damage caused by consumer misuse, tampering, or failure to follow the care and 

special handling provisions in the instructions. 

  Damage to the finish of the case, or other appearance parts caused by wear. 

  Damage caused by repairs or alterations to the product by anyone other than 

authorized by the manufacturer. 

  Freight and Insurance cost for the warranty service. 

 

       DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES 

CUSTOMER'S  SOLE  AND  EXCLUSIVE  REMEDY  UNDER  THIS  LIMITED  WARRANTY  SHALL  BE  PRODUCT  REPAIR  OR 
REPLACEMENT  AS  PROVIDED  HEREIN.  CLAIMS  BASED  ON  IMPLIED  WARRANTIES,  INCLUDING  WARRANTIES  OF 
MERCHANTABILITY  OR  FITNESS  FOR  A  PARTICULAR  PURPOSE,  ARE  LIMITED  TO  ONE  YEAR  OR  THE  SHORTEST 
PERIOD ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR. WHYNTER SHALL NOT BE LIABLE FOR CONSEQUENTIAL 
OR  INCIDENTAL  DAMAGES  SUCH  AS  PROPERTY  DAMAGE  AND  INCIDENTAL  EXPENSES  RESULTING  FROM  ANY 
BREACH  OF  THIS  WRITTEN  LIMITED  WARRANTY  OR  ANY  IMPLIED  WARRANTY.  SOME  STATES  AND  PROVINCES  DO 
NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE- QUENTIAL DAMAGES, OR LIMITATIONS ON 
THE DURATION OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS 
WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM 
STATE TO STATE. 

 

 

To obtain service or information, contact 

Whynter LLC via email at 

[email protected]

 or call  

866-WHYNTER.

 

 

 

 Product contents and specifications may change without notice.  

Copyright © 2013 Whynter LLC 

www.Whynter.com 

Summary of Contents for ARC-110WD

Page 1: ...NDITIONER co Instruction Manual MODEL ARC 110WD Congratulations on your new WHYNTER product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this...

Page 2: ...DENTIFICATION OF ACCESSORIES 6 IDENTIFICATION OF PARTS 7 INSTALLATION INSTRUCTIONS 8 9 AIR FILTERS INSTALLATION 10 REMOTE CONTROL 11 OPERATION INSTRUCTIONS 11 14 WATER DRAINAGE 14 CARE AND MAINTENANCE...

Page 3: ...provide the performance and reliability that we stand for Please keep this user manual in a safe place for future reference DISPOSAL This symbol on the product or its packaging indicates that the app...

Page 4: ...unit by yourself Always turn off the portable air conditioner when cleaning the air filter and transporting Do not turn this unit on and off by plugging and unplugging Always use the ON OFF switch Tr...

Page 5: ...ing efficiency of the portable air conditioner At the end of each season all water must be drained from the unit and filter s must be cleaned before storage THE MANUFACTURER DISCLAIMS ANY RESPONSIBILI...

Page 6: ...Y NAME QUANTITY Exhaust hose 1 small 1 large 2 pieces Fixture 2 pieces Screws 8 pieces Hose connectors 2 curved connectors are for large hose 2 straight connectors are for small hose 4 pieces Window s...

Page 7: ...CATION OF PARTS Front 1 Remote control 2 Front display 3 Air outlet 4 Handle 5 Wheels Rear 6 Air filter 7 Air intake evaporator 8 Air exhaust 9 Air intake condenser 10 Power cord 11 Upper drain port 1...

Page 8: ...out of the room to complete the air exchange of the condenser When the unit is operating in DEHUMIDIFYING or FAN only mode no exhaust is required 1 Pull out about 6 of one end of the hoses 2 Attach t...

Page 9: ...w or sliding door it will cause the window or sliding door not to be properly closed and locked Additional security measurements maybe needed 1 Open window approximately 5 2 Adjust the length of the w...

Page 10: ...to remove smoke and other order It is recommended to replace the activated carbon filter every 2 3 months Follow the steps below to install the filters WARNING NEVER OPERATE THE AIR CONDITIONER WITHOU...

Page 11: ...transmissions between the remote control and the air conditioner Remove the batteries if the remote control is not used for long periods REMOTE CONTROL PANEL Power Control Turns the unit on and off T...

Page 12: ...ing during transportation COOLING MODE In this mode the air conditioner cools and dehumidifies the room To activate this function mode press the Mode Control button until the indicator comes on When t...

Page 13: ...e is set the green light on the front panel comes on In this function mode the temperature cannot be set Subsequently set the desired fan speed by pressing the Fan Speed button Fan Only mode requires...

Page 14: ...sounds listed below are normal Noise reflecting off hard surfaces such as a floor or wall can make the sounds seem louder than they actually are The compressor may make a pulsating or high pitched so...

Page 15: ...2 3 months or as needed WARNING Never operate the air conditioner without the filter in place CLEANING THE AIR CONDITIONER Always switch off the air conditioner and disconnect the plug from the power...

Page 16: ...60Hz Maximum power input 1040 Watts Maximum input 9 5 Amps Dehumidifying capacity 81 Pts Day Thermostat 61 F to 89 F Refrigerant R 410A Air flow max 300 m3 Hour Exhaust hose length 47 Unit Dimensions...

Page 17: ...onal tolerances of the unit The Cooling mode is not on The compressor has not turned on yet because of its time delay The set temperature is too high The internal water reservoir is full This unit is...

Page 18: ...ling or another air conditioner The unit is very noisy The unit is not level The surface underneath the unit is uneven Low power voltage Make sure the unit is on hard level and stable surface Move the...

Page 19: ...e caused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage...