TROUBLESHOOTING 

Problem 

Possible Causes 

Solutions 

The portable air conditioner 
does not turn on

 

 

Power failure / outage

 

 

The automatic switch, line fuse, or 
breaker has been tripped

 

 
 
 

 

 

The power supply voltage is too low

 

 

 

The power cord is damaged

 

 

 

 

The L.C.D.I. power plug for the unit 
is tripped

 

 

The internal water reservoir is full

 

 

Restore the power supply

 

 

Flip the switch / change the fuse / turn 
the breaker back on. Also note that 
you may have too many appliances 
drawing power on one circuit, you may 
need to move the other appliances to 
another circuit

 

 

Move the unit onto another circuit with 
the correct voltage

 

 

Call for service. Only authorized per-
sonnel should replace damaged pow-
er cord or power plug

 

 

Press the Reset button on the L.C.D.I. 
power plug

 

 

Drain water from the air conditioner

 

 

Possible loose internal connection. 
Please contact Whynter for service

 

The unit turns on but the com-
pressor does not turn on (the 
fan runs but the unit is not 
cooling)

 

 

The room temperature is outside of 
the operational tolerances of the 
unit

 

 

The Cooling mode is not on

 

 

 

The compressor has not turned on 
yet because of its time delay

 

 

 

The set temperature is too high

 

 
 

 

 

The internal water reservoir is full 
and Warning Light appears on dis-
play

 

 

This unit is designed to work in ambi-
ent temperatures of 64°F to 90°F

 

 

 

Press Mode Control until the Cooling 
indicator light is shown on the display

 

 

Give the compressor 3 minutes to turn 
on after the Cooling mode has been 
selected

 

 

Set the air conditioner to a lower tem-
perature. It is recommended to set the 
temperature to at least 5°F of the am-
bient temperature

 

 

Either manually drain the water by 
removing the drain plug or allow the 
unit to exhaust the water itself by run-
ning the fan only mode. Then cooling 
will resume

 

 

Possible loose internal connection. 
Please contact Whynter for service

 

 

 

The air coming out of the unit 
is not very cold, or the airflow 
volume is weak

 

 

The filters are dirty or obstructed

 

 

The air intake or exhaust is ob-
structed

 

 

 

 

The unit is set in DEHUMIDIFY or 
FAN mode

 

 

 

The unit is set to low fan speed

 

 

Clean the air filters

 

 

Make sure there is at least 20" of 
clearance from the air intake. Make 
the length of the exhaust hose is as 
short as possible

 

 

Set the unit to Cooling mode

 

 
 

 

Set the unit to a higher fan speed

 

Many common portable air conditioner problems are easily resolved. Try the troubleshooting suggestions 

below to see if the problems can be resolved before having to contact the service department. 

Summary of Contents for ARC-101CW

Page 1: ...ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference Model ARC 101CW INSTRUCTION MANUAL WHYNTER COOLSI...

Page 2: ...ORMATION 3 SAFETY PRECAUTIONS 4 INTRODUCTION TECHNICAL DATA 5 PARTS IDENTIFICATION 6 7 CONTROL PANEL 8 INSTALLATION 9 11 OPERATION INSTRUCTIONS 12 13 REMOTE CONTROL 14 CARE AND MAINTENANCE 15 TROUBLES...

Page 3: ...cling of this product can be obtained from your local municipal au thority Thank you for choosing the Whynter CoolSize 10000 BTU Compact Portable Air Conditioner Please follow the instructions provide...

Page 4: ...sh the exhaust hose while in use Always allow at least 20 of clearance around the unit for ventilation Do not use this unit inside closets cabi nets and or cramped spaces between furniture This unit i...

Page 5: ...atures an ECO FRIENDLY CFC free GREEN R 410A refrigerant and lead free RoHS compliant components TECHNICAL DATA Model ARC 101CW Operational Modes Cool Fan or Dehumidifier Cooling Capacity 10000 BTU De...

Page 6: ...6 PARTS IDENTIFICATION Handle Control Panel Front Air Vent Louvers Air Filter Air Exhaust Power Cord Air Intake Upper Drain Port Lower Drain Port Condenser Air Intake Casters four...

Page 7: ...ent Detection and Interruption LCDI plug This plug reduces the risk of fire due to arcing faults in the power supply cord Please follow the instructions below to ensure that LCDI plug works properly 1...

Page 8: ...0 24 hours This unit is capable of displaying set tempera ture in Fahrenheit or in Celsius To convert from one to the other press and hold the and buttons for 3 seconds LCD Display In Cool mode shows...

Page 9: ...nit fully exhausts all condensation automatically in most environments when humidity is less than 70 Areas with more than 70 humidity the self evaporating function can still exhaust about 98 of the mo...

Page 10: ...t hot air must be exhausted out of the room to complete the air exchange of the condenser When the unit is operating in fan only mode installation of the exhaust hose is optional Your window kit has b...

Page 11: ...sash and outer window sash Shown in Fig 5d WINDOW KIT INSTALLATION IN A SLIDING WINDOW DOOR Additional accessory sold separately Foam Seal 1 Open window or sliding door for approx imately 5 2 Cut the...

Page 12: ...tton In cooling mode the difference in noise level between the 3 fan speeds is not very noticeable when the compressor is on Try setting the unit to Fan only mode you should be able to hear the differ...

Page 13: ...vent of a power outage the air conditioner restarts at the previously set function mode and settings when power is restored NOISE LEVEL Portable air conditioners may make sounds that are not familiar...

Page 14: ...the bottom of the battery housing close the flap once the batteries have been inserted Only use two dry LR03 AAA 1 5V Batteries included in the remote control Always change both batteries at the same...

Page 15: ...3 months or as needed Please contact info whynter com for retail sales information WARNING Never operate the air conditioner without the filter in place CLEANING THE AIR CONDITIONER Always switch off...

Page 16: ...mperature is too high The internal water reservoir is full and Warning Light appears on dis play This unit is designed to work in ambi ent temperatures of 64 F to 90 F Press Mode Control until the Coo...

Page 17: ...it is very noisy The unit is not level The surface underneath the unit is uneven Low power voltage Make sure the unit is on hard level and stable surface Move the unit to a location with a level and h...

Page 18: ...w the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations to the product by anyon...

Reviews: