INSTALLATION
Page 5
FLOOR PROTECTION - Cascade
This appliance requires noncombustible floor protection.
If the floor protection is to be stone, tile, brick, etc., it must
be mortared or grouted to form a continuous non-
combustible surface. If a chimney connector extends
horizontally over the floor, the protection must cover the
floor under the connector and at least 2" to either side.
A noncombustible floor protector must fully cover the
area beneath the appliance and extend 6” to the front, 6”
to the sides, and up to 6" from the back as illustrated be-
low.
*Note: When installed at clearances less than 6”, floor pro-
tection is only required to extend to the wall.
Note: Recommended clearance zone from the front of
the appliance to combustibles is 4 feet minimum.
MINIMUM CLEARANCES TO COMBUSTIBLES
Standard residential or manufactured (mobile) home
installation. These appliances require the following
minimum clearances to combustibles:
Manufactured (Mobile) Home
or Residential Installation
Horizontal Flue –
Directly Through
Wall
Interior Vertical
Flue
Model:
Cascade
Clearance to
Combustibles
inch / millimeter
inch / millimeter
A - Sidewall to unit
4”
/ 102 mm
4”
/ 102 mm
B - Backwall to unit
1” / 26 mm
9” / 229 mm
C - Sidewall to unit
Corner
1” / 26 mm
1” / 26 mm
D - Maximum
Depth of Alcove
•
24” / 610 mm
•
24” / 610 mm
E - Flue to Wall
3” / 77 mm
3” / 77 mm
F – Ceiling Height
above stove top
21 1/2” / 522 mm
21 1/2” / 522 mm
•
Alcove Measurements:
Height, Minimum - 49” / 1245 mm
Width Minimum - 32” / 813 mm
Depth Maximum – 24”
Rear Wall or Alcove
Corner
Rear Wall or Alcove
Minimum clearances specified may not allow for
ease of operation and maintenance (please take this
into account when planning the installation). If in-
stalled to the minimum clearances, removal of the
appliance may be necessary for servicing.
Floor
Protector
6” (152mm)
6”
(152mm)
6”
(152mm)
6” (152mm)