Stove Installation Assembly
Your Whitfield Advantage May Be Installed As:
●
A freestanding unit with a pedestal placed on a noncombustible floor pad.
●
A mobile home heater placed on a non-combustible floor pad, with a source of outside air, bolted
down and electrically grounded to the chassis of the home.
Floor Protection
Your Whitfield pellet stove must be
installed on a non-combustible pro -
tective floor pad of minimum 3/8”
thickness material or a masonr y
hearth. The hearth or floor pad must
extend a minimum of 6”in front of
and from each side of the stove or to
the nearest permitted combustible
material if less than 6”.
Clearances to
Combustibles
The following minimum clear-
ances to combustible materials
must be maintained. Keep all
combustibles at least 18”(hori-
zontally) away from the glass
windows.
(ALCOVE CLEARANCES)
Maximum Alcove depth: 24”.
Minimum Alcove height: 47-1/2”
Minimum Alcove Width: 37”
6”
6”
1”
1”
1”
6”
Floor/Hearth Pad
Hearth Pad
Combustible Wall