8. AIR SWITCH INSTALLATION
1. Drill a 1 1/4” hole in the countertop.
2. Use the rubber gasket above the counter for the air switch on the outside and tighten with plastic
nut from below your sink.
3. Attach one end of the air tube to bottom of air switch button and the other end to the bottom
center of the garbage disposal. Cut the tube to desired length.
4. Your air switch is ready to be used. Press to deploy the garbage disposal and press once again
to stop.
6. CONNECTING DISPOSAL TO EZ MOUNT
1.
Line up disposal under mounting assembly. Guide hopper projections into mount ring slots. Turn
mount ring about 1/4” to right so that the disposal is temporarily supported (see photo O).
2.
Turn mount ring and disposal until disposal elbow lines up with trap (see photo P).
3.
Turn mount ring to the right (counter-clockwise) until it locks up tight. Insert shaft of screwdriver
into slot on mount ring and tighten until the lock position is achieved. Hopper projections must be to
extreme left of mounting slots (see photo Q).
4.
If mount ring is hard to turn, you may add a small amount of petroleum jelly or liquid soap to
hopper projections. Run water and check for leaks.
P
Q
O