![WHITECROFT LIGHTING Mini Spot 65 Installation Leaflet Download Page 2](http://html1.mh-extra.com/html/whitecroft-lighting/mini-spot-65/mini-spot-65_installation-leaflet_977083002.webp)
INSTALLATION SEQUENCE
In order to fit this luminaire, the correct sequence of assembly must be observed.
All measurements in mm unless stated otherwise
1. Remove the fitting from all of the packaging.
Optional To change lens colour: Remove screws on back of lamp housing before
releasing standard lens via the holding screws (Fig. 1). Replace
standard lens with coloured lens and re-assemble lamp housing.
Optional Attaching cowl / shutter accessory: Dissemble lamp housing (see
change lens step) and attach cowl or shutter using an Allen key (Fig. 2).
Avoid water pooling in cowl by angling luminaire downwards.
When fitting accessories ensure small O-rings are not lost
2. Remove the 4 fixing screws securing the luminaire body to the base (Fig. 3).
3. Surface mounting: Secure luminaire base to desired surface in correct orientation
using appropriate fixings (by others) via surface mounting holes (Fig. 3).
Optional Ground spike mounting: Attach the mounting spike to the base (if
specified) using the screws supplied via the spike mounting holes
(Fig. 4) and secure the mounting spike into the ground.
4. Feed the 2 core supply flex (
Ø
9 min - 12 max) through the grommet (Fig. 5).
5. Strip the correct length of wire and neatly connect the 2 core supply flex to the
Live/Neutral (Fig. 5).
6. Re-attach the luminaire body to the base using the 4 fixing screws (Fig. 3)
Fig. 4
[ Ground Spike Attachment ]
Fig. 1
[ Filter Lens Fitting ]
Fig. 2
Shutter Accessory
Cowl Accessory
[ Shutter / Cowl Fitting ]
Fig. 3
156
100
97
Fixing screws
Surface mount fixings (by others)
[ Luminaire Base Assembly ]
Raw plugs (by others)
8
Fig. 5
[ Wire Preparation ]
F / N = L / N
Adjust light direction using a suitable Allen key
( Angle rotation limited to 280° approx. )
25