Mini-Seis III Pro™ Operating Manual
Page 29
Event Screen Functions
There are two types of records that can be displayed on the Event Screen, waveform and
histogram.
Waveform Events
BAT: 6.5V
EVENT: 00002
08-28-2020 11:20:42
IPS/dB
Hz
CAL
V: 0.114
9.85
OK
R: 0.802
16.78 OK
T: 0.684
7.42
OK
A: 125.0
33.7
OK
Histogram Events
BAT: 6.5V
JOB: 00003
08-28-2020 11:40:37
IPS/dB
Hz
CAL
V: 0.237
9.85
OK
R: 0.115
16.78
OK
T: 0.213
7.42
OK
A: 113.0
33.7
OK
The OK under CAL means that the sensor self-test responded within acceptable parameters
when sent a test pulse. This action does not calibrate the sensor, nor is it an indication of
whether or not a sensor is in calibration. The calibration of a sensor can only be tested and
adjusted with the proper equipment.
Copy
The Copy soft key is used to write records to a USB thumb drive. A special cable is
provided for this purpose. It has a female DB9 connector on one end and a USB connector
for a thumb drive on the other end. The cable uses the male DB9 connector on the
seismograph.
C
OPY
E
VENT
O
PTIONS
The Copy Event Options display gives us three copy options. All, Range or Date. The
appearance of the display depends on the selected option.
Copy
diY
Back
Back
Copy